Instruction Manual
D200160X012
4195K Controllers
July 2018
96
shaft in the middle of the bushing end play. Be sure neither bushing is resting against the inside end of either
bearing. Tighten the drive flexure screws to hold the pivot shaft in this position. Do not bend or twist the flexure
when tightening the screws.
4. Decrease the remote set point pressure to 0 bar (0 psig).
5. Perform the remote set point maintenance calibration procedure. Perform the appropriate process indicator zero
and span calibration and flapper alignment procedure in Section 3, 4, or 5.
Replacing the Remote Set Point Tubing
1. Decrease the remote set point pressure to 0 bar (0 psig).
2. Using two 5/16‐inch open‐end wrenches, disconnect the pressure connection union (key 93) from the pedestal
assembly (key 105) and the connection to the case exterior at the top of the case.
3. Remove the tubing (key 104).
4. Install the replacement tubing, and reconnect the two pressure connections.
5. Apply full remote set point pressure, and check for leaks.
Replacing Link A
1. Note the holes where link A is connected. Disconnect link A (key 116) from the lever arms on pivot assembly A and
pivot assembly B.
2. Loosen the screw in the replacement link A and adjust the length to match the link being replaced. Tighten the
screw.
4. Perform the remote set point maintenance calibration procedure. Perform the appropriate process indicator zero
and span calibration and flapper alignment procedures in Section 3, 4, or 5.
Replacing Link B
1. Note the holes where link B is connected. Disconnect link B (key 126) from the pivot arm and from the set point
indicator.
2. Loosen the screw in the replacement link B and adjust the length to match the link being replaced. Tighten the
screw.
point indicator in the same holes as noted in step 1.
4. Perform the remote set point maintenance calibration procedure. Perform the appropriate process indicator zero
and span calibration and flapper alignment procedures in Section 3, 4, or 5.
Remote Set Point (suffix letter M) Maintenance Calibration
Refer to figure 6‐23 for parts and adjustment locations. Refer to figures 7‐1 and 7‐6 for key number locations.
Precalibration Procedure
WARNING