F02/EPI2 Quarter-Turn
Electric Actuator
Base and OM1 Card
F02/EPI2 Base and OM1 Card
April 2018
Quick Start Guide
VCIOM-08536-US Rev. 0
Base Card
F02/EPI2 Quarter-Turn Electric Actuator
Figure 1
Model 063-125
Green LED
Power ON
Dip switch
SW3
Push button
SW5
Red LED
Enter configuration
Rotary switch
SW4
Rotary switch
SW6
Figure 2
Model 250-500-1000-2000
Dip switch
SW3
Green LED
Power ON
Rotary switch
SW6
Rotary switch
SW4
Red LED
Enter configuration
Push button
SW5
Table 1.
Operating Times
Model
Nominal torque
(Nm/lb.in.)
Operating time (secs 90
o
) at selected step
8
6
4
063
63/600
15
28
48
125
125/1300
15
28
48
250
250/2500
15
28
48
500
500/5100
15
28
48
1000
1000/9100
24
45
80
2000
2000/17700
53
100
180
Note:
(*) Factory
PRE-INSTALLATION:
See
VCIOM-2881
INSTALLATION AND MAINTENANCE INSTRUCTIONS. Not performing the following procedures will invalidate the product warranty.
INSTALLATION:
To assemble the actuator onto the valve proceed as follows:
a. Verify proper mounting hardware.
b. Verify proper electrical service to the actuator
c.
Lubricate the valve stem with oil or grease to make the assembly easier: pay attention not to contaminate with lubricant the flange surfaces which transmit the actuator torque.
d.
Clean the valve flange and remove anything that might prevent a perfect adherence to the actuator flange and especially all traces of grease.
e. Install the actuator onto the valve so that the shaft out put drive enters the groove of the stem extension. This coupling must take place without forcing and only with the weight of the
actuator.
f.
Ensure actuator and valve are in same orientation when bolting together.
g. With the handwheel, operate the actuator to verify it moves the valve smoothly.
WARNING
The configuration must be done while the actuator is powered on. As a consequence, all configuration operations must be carried out by specifically qualified personnel for operations on
powered electronic cards. Hazardous voltages may be present. Before connecting power to the actuator, check that the voltages are correct and according to the nameplate data. Improper power
supply will cause permanent damage to the electrical components. Actuator configuration programming requires removal of the actuator cover. Refer to VCIOM-2881 IOM for instructions.
Quick Start Guide
VCIOM-08536-US Rev. 0
F02/EPI2 Base and OM1 Card
April 2018
See
table 1
Rotary Switch Settings
Configurations
Move switch
SW4
to position
indicated in each row
Move switch
SW6
to position
indicated in each row
SW3
Confirm by
SW5
Red
LED
SW3
CLOSE LIMIT by position
2
1 (*)
En
te
r s
et u
p c
onfigur
ati
on m
ovin
g S
W3 t
o O
N
PUS
H
LED lights up once
Exit s
et u
p c
onfigur
ati
on m
ovin
g S
W3 t
o 1 (R
un Se
ttin
g)
Drive the actuator to
the CLOSE position
using the handwheel
0
0
OPEN LIMIT by position
3
1 (*)
LED lights up once
Drive the actuator to
the OPEN position
using the handwheel
1
0
CLOSE LIMIT by torque
2
0 (*)
Operate the
actuator to direction
bylocal/remote
control and wait
until it stops by
torque
OPEN LIMIT by torque
3
0 (*)
CLOSING speed
4
4
6 (*)
8
LED lights up once
OPENING speed
5
% CLOSING torque
6
2
= 50%
5
= 75%
9 = 100% (*)
% OPENING torque
7
CW/CCW
8
0 = CW (*)
1
= CCW
BLINKER/local selector
4
0 = off (*)
1
= Blinker
2
= Loc. Sel.