5-1
L3202EA
ELECTRICAL ADJUSTMENT INSTRUCTIONS
General Note: “CBA” is abbreviation for
“Circuit Board Assembly.”
Note:
Electrical adjustments are required after
replacing circuit components and certain
mechanical parts. It is important to perform
these adjustments only after all repairs and
replacements have been completed.
Also, do not attempt these adjustments unless
the proper equipment is available.
Test Equipment Required
1. DC Voltmeter
2. NTSC Pattern Generator (Color Bar W/White
Window, Red Color, Dot Pattern, Gray Scale,
Monoscope, Multi-Burst)
3. Remote control unit: Part No. N0105UD or
N0127UD
4. Color Analyzer
How to make Service remote
control unit:
1. Prepare normal remote control unit.
(Part No. N0105UD or N0127UD)
Remove 3 Screws from the back lid. (Fig. 1-1)
2. Added J1 (Jumper Wire) to the remote control
CBA. (Fig. 1-2)
How to set up the service mode:
Service mode:
1. Use the service remote control unit.
2. Turn the power on. (Use main power on the TV
unit.)
3. Press [SLEEP] button on the service remote
control unit. Version of micro computer will be
displayed on the LCD or display. (Ex: 0004FP-
0.47)
1. Initial Setting
General:
Enter the Service mode. (See page 5-1.)
Set the each initial data as shown on table 1 below.
Table 1: Initial Data
Fig. 1-1
Screws
Remote control unit (bottom)
Fig. 1-2
J 1
Remote Control CBA
Item
Button
(on the service
remote control)
Data
Value
BRT
[MENU]
→
[1]
133
CNT
180
CLR-R
66
CLR-B
68
TNT
64
V-TNT
64
SHR
28
S-BRT
[MENU]
→
[2]
141
S-CNT
180
S-CLR-R
69
S-CLR-B
60
S-TNT
63
S-SHR
35
C-BRT
[MENU]
→
[3]
133
C-CNT
180
C-CLR-R
70
C-CLR-B
66
C-TNT
60
C-SHR
35
Summary of Contents for EWL2005