background image

 

XW60K 110918 V14.7 EMERSON092718 V14.7 

XW60K 

11/12 

 

Label 

Name 

Range 

Default 

Level 

 

Delay of temperature alarm at start up 

0.0 to 23h50min, res. 10 min 

2.30 

Pr2 

 

Probe for temperat. alarm of condenser 

nP; P1; P2; P3; P4 

P4 

Pr2 

 

Condenser for low temperat. alarm 

[-55.0 to 150.0°C] 

[-67 to 302°F] 

-58 

Pr2 

 

Condenser for high temperat. alarm 

[-55.0 to 150.0°C] 

[-67 to 302°F] 

230 

Pr2 

 

Differential for condenser temperature alarm 
recovery 

[0.1 to 25.5°C] 

[1 to 45°F] 

10 

Pr2 

 

Condenser temperature alarm delay 

0 to 254 min , 255=nU 

15 

Pr2 

 

Delay of cond. temper. alarm at start up 

0.0 to 23h50min, res. 10 min 

2.30 

Pr2 

 

Solenoid off because of condenser low 
temperature alarm 

n(0); Y(1) 

no 

Pr2 

 

Compr. off for condenser high temperature alarm 

n(0); Y(1) 

no 

Pr2 

AUXILIARY OUTPUT

 

 

Alarm relay disabling 

n=no; Y=yes 

yes 

Pr2 

 

Fourth relay configuration (22-23) 

ALr = alarm; dEF = do not select it; Lig =Light; AUS =AUX; 

onF=always on; Fan= do not select it; db = the output is set as heat; 

Cp2=second compressor 

dF2 = second defrost 

LiG 

Pr2 

 

Alarm relay polarity (if oA3=ALr) 

oP; CL 

CL 

Pr2 

DIGITAL INPUT

 

 

Digital input polarity 

oP=opening;CL=closing 

CL 

Pr1 

 

Digital input configuration on KeyPad 

EAL; bAL; PAL; dor; dEF; ES: Htr; FAN;ONF; AUS; LHT 

EAL 

Pr1 

 

Digital input alarm delay 

0 to 255 min 

15 

Pr1 

 

Second Digital input on base 

n , y  

no 

Pr2 

 

Digital input polarity 

oP=opening;CL=closing 

CL 

Pr1 

 

Second Digital input configuration 

EAL; bAL; PAL; dor; dEF; ES: Htr; FAN;ONF; AUS; LHT 

dor 

Pr1 

 

Digital input alarm delay 

0 to 255 min 

Pr1 

 

Number of activation of pressure switch 

0 to 15 

15 

Pr2 

 

Compress and fan status when open door 

no; FAn; CPr; F_C 

F-C 

Pr2 

 

Regulation restart with door open alarm 

n; Y 

yes 

Pr2 

 

Light off during energy saving status 

n; Y 

no 

Pr2 

 

Differential for Energy Saving 

[-30 to 30°C]  [-54 to 54°F] 

Pr2 

Current hour 

read only (after first set up) 

rtc 

Current minute 

read only (after first set up) 

rtc 

Current day 

read only (after first set up) 

rtc 

Day of the month 

read only (after first set up) 

rtc 

*

 

Month 

read only (after first set up) 

rtc 

*

 

Year 

read only (after first set up) 

rtc 

First weekly holiday 

Sun to SAt; nu 

nu 

rtc 

Second weekly holiday 

Sun to SAt; nu 

nu 

rtc 

Energy Saving cycle start during workdays 

0.0 to 23h50min 

rtc 

Energy Saving cycle length during workdays 

0.0 to 24h00min 

rtc 

Energy Saving cycle start on holidays 

0.0 to 23h50min 

rtc 

Energy Saving cycle length on holidays 

0.0 to 24h00min 

rtc 

1

st

 workdays defrost start 

0.0 to 23h50min; nu 

6.0 

rtc 

2

nd

 workdays defrost start 

0.0 to 23h50min; nu 

13.0 

rtc 

3

rd

 workdays defrost start 

0.0 to 23h50min; nu 

21.0 

rtc 

4

th

 workdays defrost start 

0.0 to 23h50min; nu 

0.0 

rtc 

5

th

 workdays defrost start 

0.0 to 23h50min; nu 

0.0 

rtc 

6

th

 workdays defrost start 

0.0 to 23h50min; nu 

0.0 

rtc 

1

st

 holiday defrost start 

0.0 to 23h50min; nu 

6.0 

rtc 

2

nd

 holiday defrost start 

0.0 to 23h50min; nu 

13.0 

rtc 

3

rd

 holiday defrost start 

0.0 to 23h50min; nu 

21.0 

rtc 

4

th

 holiday defrost start 

0.0 to 23h50min; nu 

0.0 

rtc 

5

th

 holiday defrost start 

0.0 to 23h50min; nu 

0.0 

rtc 

Summary of Contents for dixell XW60K

Page 1: ...ogress a continuous chill mode can be activated by holding the oUP key pressed for about 3 sec The solenoid operates to maintain the CCS set point for the time set through the CCt parameter The cycle can be terminated before the end of the set time by pressing theo UP key for 3 sec 3 3 DEFROST ON DEMAND OR RTC OPTIONAL MUST BE ORDERED Hot Gas or Electric Defrost can be managed through the tdF para...

Page 2: ...ion for the auxiliary relay Ht heating CL cooling SAA 40 230 F Set point for auxiliary relay SHy 0 25 F Differential for auxiliary output With ACH CL aux relay cut in is SAA SHy cut out SAA With ACH Ht aux relay cut in is SAA SHy cut out SAA ArP nP P1 P2 P3 P4 Probe for auxiliary relay Sdd n Y Auxiliary output working during defrost 4 5 ALARM RELAY OA3 ALR OPTIONAL By setting oA3 ALr the relay wil...

Page 3: ...arameter is also present in Pr1 ON Continuous cycle is running ON Energy saving enabled ON Light on ON Auxiliary relay on C F ON Measurement unit 6 AUTOMATIC KEYBOARD LOCK ONLY FOR T620T To avoid accidental modifications of the controller settings the T620T keyboard will be locked automatically if no key will be touched for 60 seconds The T620T will show LoC flashing for few seconds when it s lock...

Page 4: ...ming mode 2 Select the required parameter with UP or DOWN 3 Press the SET key to display its value and LED starts blinking 4 Use UP or DOWN to change its value 5 Press SET to store the new value and move to the following parameter To exit Press SET UP or wait for 15 sec without pressing any key NOTE the new programming is stored even when the procedure is exited by waiting the time out 7 8 HOW TO ...

Page 5: ...d defrosts to start together dFd Temperature displayed during defrost rt it SEt dEF rt real temperature it temperature at defrost start SEt set point dEF dEF label dAd MAX display delay after defrost 0 to 255min sets the maximum time between the end of defrost and the restarting of the real room temperature display Fdt Drip time 0 to 120min is the interval time between reaching defrost termination...

Page 6: ...ls 8 9 D I i2P Second digital input polarity oP CL oP the digital input is activated by opening the contact CL the digital input is activated by closing the contact i2F Second digital input configuration EAL bAL PAL dor dEF ES AUS Htr FAn HdF onF Sbt EAL external alarm EA message is displayed bAL serious alarm CA message is displayed PAL pressure switch alarm CA message is displayed dor door switc...

Page 7: ...th oA3 AUS and i1F AUX it switches the fourth relay 22 23 10 6 START DEFROST I1F DFR OPTIONAL It starts a defrost if there are the right conditions After the defrost is finished the normal regulation will restart only if the digital input is disabled otherwise the instrument will wait until the MdF safety time is expired 10 7 KIND OF ACTION HEATING OR COOLING I1F HTR OPTIONAL This function allows ...

Page 8: ...ments are provided with an internal check for the data integrity The EE alarm flashes when a failure in the memory data occurs In such cases the alarm output is enabled 13 3 ALARM RECOVERY Probe alarms P1 probe1 faulty P2 P3 and P4 they automatically stop 10 sec after the probe restarts normal operation Check connections before replacing the probe Temperature alarms HA LA HA2 and LA2 automatically...

Page 9: ...n a 71x29mm panel cut out Frontal protection IP65 with frontal gasket Connections Screw terminal block 2 5 mm2 Power supply from XW60K power module Display 3 digits red LED 14 2 mm high Alarm Output buzzer Power module XW60K Case 8 DN 140X176X148 Connections Screw terminal block 2 5 mm2 heat resistant wiring and 6 3mm Faston Power supply 230Vac or 110Vac 10 or 24Vac Power absorption 6VA max Inputs...

Page 10: ...30 Pr1 Start defrost delay 0 to 99 min 0 Pr2 Displaying during defrost rt it SEt dEF dEG DEF Pr2 MAX display delay after defrost 0 to 255 min 30 Pr2 Draining time 0 to 60 min 1 Pr2 First defrost after start up n Y n Pr2 Defrost delay after fast freezing 0 0 to 23h50min res 10 min 0 00 Pr2 FANS Fans operating mode C n C y O n O y O_n Pr1 Fans delay after defrost 0 to 255 min 10 Pr1 Differential of ...

Page 11: ... dEF ES Htr FAN ONF AUS LHT dor Pr1 Digital input alarm delay 0 to 255 min 0 Pr1 Number of activation of pressure switch 0 to 15 15 Pr2 Compress and fan status when open door no FAn CPr F_C F C Pr2 Regulation restart with door open alarm n Y yes Pr2 Light off during energy saving status n Y no Pr2 Differential for Energy Saving 30 to 30 C 54 to 54 F 0 Pr2 Current hour read only after first set up ...

Page 12: ...r1 Evaporator probe display read only Pr1 Third probe display read only Pr1 Fourth probe display read only Pr1 Current set point read only Pr1 Software release read only Pr2 Map code read only Pr2 18 CERTIFICATIONS 19 FOR WARRANTY AND OTHER INFORMATION 1065 Big Shanty Road Suite 100 Kennesaw GA 30144 www emerson com Support Phone 770 425 2724 select option 2 SolutionsTechSup Emerson com Sales solu...