TECHNICAL DATA 

FEATURES

 

DESCRIPTION

 

Housing

 

Self-extinguishing PC/PC+ABS 

Dimensions

 

Frontal 38x80 mm; depth 62mm 

Mounting

 

Panel mounting device in a 71x29mm panel cut-out 

Degree of Protection

 

NEMA (UL 50e)

 

Indoor use only, type 1 enclosure 

IP (IEC/EN 60529)

 

Front panel: IP65; Rear housing: IP00 

Power Supply

 

According to the model: 12VAC/DC, ±10%; 24VAC/DC, ±10%; 110VAC ±10%, 50/60Hz; 230VAC ±10%, 50/60Hz 

Overvoltage Category

 

II 

Rated Power

 

12VAC/DC: 3VA max; 24VAC/DC: 3VA max; 110VAC or 230VAC: 4VA 

Rated Impulse Voltage

 

2500V 

Software Class

 

Terminal blocks / Terminal Connections

 

Plug-in or screw terminal block, wire section between 1 and 2,5 mm2 
Max tightening force: 0.5 N*m for 5,0mm pitch 

Data Storing

 

Real Time Clock:

 Data maintenance up to 6 months with lithium battery.  

Other parameters:

 internal EEPROM. 

Type of Action

 

1.B 

Pollution Degree

 

2, non-condensing humidity 

Ambient Operating Temperature and 
Humidity

 

IEC/EN 

0T60°C; 20-85 rH% (non-condensing humidity) 

UL-CAN/CSA 

-20T60°C; 20-85 rH% (non-condensing humidity) 

Shipping and storage temperature

 

-40T85°C; 20-85 rH% (non-condensing humidity)  

Resistance to Heat

 

UL 94 V-0 

Measurement range

 

NTC:

 -40T110°C, resolution 0.1°C or 1°C (selectable) 

PT1000:

 -100T150°C, resolution 0.1°C or 1°C (selectable) 

PTC:

 -50T150°C, resolution 0.1°C or 1°C (selectable) 

Accuracy

 

±0.7°C ±1 digit and relative to the full scale 

Inputs

 

4 NTC, PTC or PT1000 (configurable); 1 voltage free contacts 

I/O port

 

HOT-KEY: MAX voltage allowed is 5 VDC. DO NOT CONNECT ANY EXTERNAL POWER SUPPLY. 

Buzzer

 

Optional 

Serial Outputs

 

TTL standard available on 5-pin port (HOT-KEY connector); Maximum cable length = 2m 

Relay Outputs (standard)

 

Ref

 

Nominal 

UL 

IEC 

oA1 

SPST 20A, 

250VAC 

Resistive load 16A, 120/250Vac, 100K cycles  

Motor load 1HP (16FLA/96LRA), 120Vac, 30K cycles  
Motor load 2HP (12FLA/72LRA), 240Vac, 30K cycles  

20A, 250Vac, 30K cycles 

oA2 

SPST 8A, 

250VAC 

Resistive load 10A, 120/240Vac, 30K cycles  

Motor load 1/4HP, 120Vac, 30K cycles  
Motor load 1/2HP, 240Vac, 30K cycles  

Resistive load 8A, 30Vdc, 30K cycles  

8(3)A, 230Vac, 30K cycles 

oA3 

SPST 5A, 

250VAC 

Resistive load 5A, 120/250Vac, 30K cycles  

Inductive (general purpose) 5A, 120/250Vac, 30K cycles  

Motor load 1.9FLA/11.4LRA, 120/250Vac, 30K cycles  

Pilot duty 180VA, 250V, 30K cycles  

5A, 230Vac, 30K cycles 

Maximum ampacity (common terminal 1)

  16A 

Analogue Outputs

 

Freq 

Frequency output; Supply max voltage = 12Vdc; Max supply current = 10mA; Duty cycle = 50%; Range = 0 to 166 Hz; 
Maximum cable length = 10m 

Purpose of control

 

Operating control 

Construction of control

 

Incorporated control, intended to be used in Class I or Class II equipment 

Approvals

 

R290/R600a: relays tested according to IEC EN60079:0 and IEC EN60079:15  
IEC/EN 60730-1; IEC/EN 60730-2-9  
UL 60730-1; UL 60730-2-9  
CAN/CSA-E60730-1; CAN/CSA-E60730-2-9  

 

 

 

Summary of Contents for Dixell XRi60CH

Page 1: ...porator s probe P2P At the end of defrost dripping time is started its length is set in the Fdt parameter With Fdt 0 the dripping time is disabled 3 2 1 PRE DEFROST The par dAF enable a pre defrost phase During this interval the regulation setpoint will be moved to the value SET 1 C or SET 1 F The defrost phase starts as soon as the regulation temperature reach the pre defrost setpoint or when the...

Page 2: ...the maximum compressor speed FMA until reaching the CCS setpoint The maximum interval of time for any PULL DOWN is defined from par CCt 8 2 OIL MIGRATION CONTROL VALID ONLY FOR VSC To avoid oil migration during variable speed compressor operation a lubrication control is implemented If the compressor works with a speed lower than the MnP threshold for tMi time then the compressor speed will be inc...

Page 3: ...T HY1 Variable Speed Compressor Differential in normal mode 0 1 to 25 5 C 1 to 45 F odS Output activation delay at start up 0 to 255 min this function is enabled after the instrument power on and delays the output activations AC Anti short cycle delay 0 to 999 sec minimum interval between a compressor stop and the following restart AC1 Anti short cycle delay 2nd compressor 0 to 999 sec delay befor...

Page 4: ...ating CL cooling SAA Set Point for auxiliary regulator 100 0 to 150 0 C 148 to 302 F it defines the room temperature set point to switch auxiliary relay SHY Auxiliary regulator differential 0 1 to 25 5 C 1 to 45 F differential for auxiliary output set point ACH CL AUX Cut in is SAA SHY AUX Cut out is SAA ACH Ht AUX Cut in is SAA SHY AUX Cut out is SAA ArP Probe selection for auxiliary regulator nP...

Page 5: ...lease for internal use Ptb Parameter table code readable only 13 DIGITAL INPUTS The first digital input terminals 18 20 is enabled with P3P n The free voltage digital inputs are programmable by the i1F parameter 13 1 GENERIC ALARM i1F EAL As soon as the digital input is activated the unit will wait for did time delay before signalling the EAL alarm message The outputs status doesn t change The ala...

Page 6: ...l operation Check connections before replacing the probe Temperature alarms HA and LA automatically stop as soon as the temperature returns to normal values Alarms EA and CA with ixF bAL PAL recover as soon as the digital input is disabled 18 3 OTHER MESSAGES Pon Keyboard unlocked PoF Keyboard locked noP In programming mode no parameter in Pr1 On the display or in dP2 dP3 dP4 the selected probe is...

Page 7: ...tor fan controlled during defrost no no Pr2 Fon Evaporator fan ON time in normal mode with compressor OFF 0 0 Pr2 min FoF Evaporator fan OFF time in normal mode with compressor OFF 0 0 Pr2 min FAC Probe selection for condenser fan nP nP Pr2 St2 Set Point 2 Regulation for condenser fan 0 0 15 0 Pr2 C Hy2 Set Point 2 differential for condenser fan 1 0 10 0 Pr2 C FCC Condenser fan operating mode O_n ...

Page 8: ...0 Pr2 hh mm Adr Serial address 1 1 Pr2 bAU Baudrate 9 6 9 6 Pr2 onC ONOFF button configuration left upper side nU nU Pr2 on2 ONOFF button timed 3sec configuration left upper side oFF oFF Pr2 LGC Light button configuration left upper side LiG LiG Pr2 LG2 Light button timed 3sec configuration left upper side nU nU Pr2 dFC DEF button configuration left upper side Pb2 Pb2 Pr2 dF2 DEF button timed 3sec...

Page 9: ...50T150 C resolution 0 1 C or 1 C selectable Accuracy 0 7 C 1 digit and relative to the full scale Inputs 4 NTC PTC or PT1000 configurable 1 voltage free contacts I O port HOT KEY MAX voltage allowed is 5 VDC DO NOT CONNECT ANY EXTERNAL POWER SUPPLY Buzzer Optional Serial Outputs TTL standard available on 5 pin port HOT KEY connector Maximum cable length 2m Relay Outputs standard Ref Nominal UL IEC...

Reviews: