4.10 PARAMETER MENU
When in
Programmin Menu
, it is possible to enter the
Parameter Menu
touching the
PRG
icon for 3 sec.
The
Prog Level 1
icon will indicate the first level of the programming menu (group labels).
The
Browsing
icon will indicate that there are other groups of parameters.
…
When in
PROG LEVEL 1
, it is possible to browse through the available groups of parameters by using the H-
swipe gesture. The circular construction of this menu permits to move left or right through the groups.
Here are the available groups:
Group Label
Description
rEG
Main regulation parameters
Prb
Probe configuration parameters
diS
Visualization parameters
dEF
Defrost configuration parameters
FAn
Evaporator and condenser fan configuration parameters
AUS
Auxiliary regulator parameters
ALr
Alarm configuration parameters
oUt
Digital and analogue output configuration parameters
inP
Digital input configuration parameters
ES
Energy saving configuration parameters
Cnt
Counters, read only values
rtC
Real Time Clock configuration parameters
E2
Memory storage management
CoM
Serial Communication port configuration parameters
Ui
User Interface configuration parameters
inF
Information, read only parameters
PAS
Password for entering protected menu parameters
4.11 PASSWORD MENU
When in the
PAS
group, it is possible to set the password value by touching the
PRG
icon for 3 sec.
V-swipe on a single digit to modify the value, then confirm the password value by touching the
PRG
icon for
3 sec.
The new value will blink and after 2 sec the display will show:
•
Pr2
if the password is correct
Summary of Contents for Dixell XR70T
Page 1: ...XR70T Full Touch V 1 0 ...
Page 2: ......
Page 39: ...1592040000 XR70T EN v1 1 2019 07 09 XR70T 39 40 ...
Page 40: ...1592040000 XR70T EN v1 1 2019 07 09 XR70T 40 40 ...