Emerson Dixell XR10C Installating And Operating Instructions Download Page 1

 

1592007201 XR10C-D GB r1.0 18.11.2015 

XR10C – XR10D 

1/4 

Digital controller with cooling or heating action

 

XR10C 

– XR10D

 

1.  GENERAL WARNING 

1.1  PLEASE READ BEFORE USING THIS MANUAL 

 

This manual is part of the product and should be kept near the instrument for 
easy and quick reference. 

 

The instrument shall not be used for purposes different from those described 
hereunder. It cannot be used as a safety device. 

 

Check the application limits before proceeding. 

 

Dixell  Srl  reserves  the  right  to  change  the  composition  of  its  products,  even 
without notice, ensuring the same and unchanged functionality. 

1.2 

 SAFETY PRECAUTIONS 

 

Check the supply voltage is correct before connecting the instrument. 

 

Do  not  expose  to  water  or  moisture:  use  the  controller  only  within  the 
operating limits avoiding sudden temperature changes with high atmospheric 
humidity to prevent  formation of condensation 

 

Warning:  disconnect  all  electrical  connections  before  any  kind  of 
maintenance. 

 

Fit the probe where it is not accessible by the End User. The instrument must 
not be opened. 

 

In  case  of  failure  or  faulty  operation  send  the  instrument  back  to  the 
distributor or to “Dixell S.r.l.” (see address) with a detailed description of the 
fault. 

 

Consider  the  maximum  current  which  can  be  applied  to  each  relay  (see 
Technical Data). 

 

Ensure  that  the  wires  for  probes,  loads  and  the  power  supply  are  separated 
and far enough from each other, without crossing or intertwining. 

 

In case of applications in industrial environments, the use of mains filters (our 
mod. FT1) in parallel with inductive loads could be useful. 

2.  GENERAL DESCRIPTION 

Models 

XR10C

,  format  32  x  74  mm,  and 

XR10D

,  DIN  rail  format,  are  a  single 

stage temperature controllers suitable for applications  in the field of refrigeration 
or  heating.    It  provides  a  relay  output  and  a  PTC  or  NTC  probe  input.  The 
instrument  is  fully  configurable  through  special  parameters  that  can  be  easily 
programmed through the keyboard.  

3.  CONTROLLING LOADS 

3.1  THE REGULATION OUTPUT 

The regulation is performed according to the temperature measured by the probe. 
The  instruments  are  provided  with  the 

CH 

programmable  parameter  which 

enables the user to set the regulation both for heating or cooling applications:

 

· 

 CH = CL: cooling applications

  

· 

 

CH = Ht: heating applications

 

3.2  CH = CL: COOLING APPLICATIONS. 

The  Hy  value  is  automatically  set  above  the  Set  Point.  If  the  temperature 
increases  and  reaches  set  point  plus  differential  the  compressor  is  started  and 
then turned off when the temperature reaches the set point value again.  
 

 

 

3.3  CH = HT: HEATING APPLICATION.  

The  Hy  value  is  automatically  set  under  the  Set  Point.  If  the  temperature 
decreases  and  reaches  set  point  minus  differential  the  regulation  output  is 
activated  and  then  turned  off  when  the  temperature  reaches  the  set  point  value 
again. 
 

 

 
 
 
 

4.  FRONT PANEL COMMANDS 

 

XR10C 

LED1

 

 

XR10D 

LED1

 

 

SET

: To display target set point; in programming mode it  selects a parameter  or 

confirm an operation. 

o

  (

UP)

:  To  see  the  last  temperature  alarm  happened;  in  programming  mode  it 

browses the parameter codes or increases the displayed value. 

n

 (

DOWN

) To see the last temperature alarm happened; in programming mode it 

browses the parameter codes or decreases the displayed value. 

KEY COMBINATIONS: 

n



To lock & unlock the keyboard

.

 

SET +

 

n

  To enter in programming mode. 

SET + 

o  

To return to the room temperature display. 

4.1  USE OF LEDS 

Each LED function is described in the following table. 

LED  MODE 

FUNCTION 

 

ON 

Output enabled 

 

Flashin

-Programming Phase (flashing with LED1) 
- Anti-short cycle delay enabled 

LED1  Flashin

- Programming Phase (flashing with 

 

ON 

An temperature alarm happened 

5.  TEMPERATURE ALARM AND ITS DURATION 
RECORDING (HACCP) 

XR10C  signals  and  records  temperature  alarms,  together  with  their  duration  and 
max value reached. See drawing: 

 
Ex. High temperature alarm 

 

Set

ALu

High temp. alarm

Time

Temperature

ALL

Low temp. alarm

X

X

X

Alarm duration

Max

Temperature

Safe food zone

 

5.1  HOW TO SEE THE ALARM DURATION AND MAX (MIN) 
TEMPERATURE  

If the alarm LED is on, an alarm has taken place.  
To see the kind of alarm, the max (min) reached temperature and alarm duration 
do as follows: 
1. 

Push the Up or Down key. 

2. 

On the display the following message is shown:: 

HAL

”  for  high  temperature  alarm  (“

LAL

”  fot  the  minimum  allarm),  followed 

by the 

Maximum (minimum) temperature. 

Then  the  “

tiM

”  (

tiM

e)  message  is  displayed,  followed  by  the 

“Duration” 

in 

h.mm. 

3. 

Then the instrument displays the temperature once again. 

 

NOTE1: 

if an alarm is still occurring the “

tim

” shows the partial duration. 

NOTE2:

 the alarm is recorded when the temperature come back to normal values 

5.2  HOW TO RESET A RECORDED ALARM OR ONE THAT IS 
STILL OCCURRING 

1.  Hold  the  SET  key  pressed  for  more  than  3s,  while  the  recorded  alarm  is 

displayed. (the rSt message will be displayed) 

2. 

To  confirm  the  operation,  the  “rSt”  message  starts  blinking  and  the  normal 
temperature will be displayed. 

Summary of Contents for Dixell XR10C

Page 1: ...ly set above the Set Point If the temperature increases and reaches set point plus differential the compressor is started and then turned off when the temperature reaches the set point value again 3 3 CH HT HEATING APPLICATION The Hy value is automatically set under the Set Point If the temperature decreases and reaches set point minus differential the regulation output is activated and then turne...

Page 2: ...eating DISPLAY CF Temperature measurement unit C Celsius F Fahrenheit WARNING When the measurement unit is changed the SET point and the values of the parameters Hy LS US Ot ALU and ALL have to be checked and modified if necessary rES Resolution for C in 1 C dE 0 1 C allows decimal point display ALARMS ALC Temperature alarms configuration Ab rE Ab absolute temperature alarm temperature is given by...

Page 3: ... flashing End 4 After 10 seconds the instrument will restart working with the new parameters 5 Remove the Hot Key NOTE the message Err is displayed for failed programming In this case turn the unit off and then on if you want to restart the download again or remove the Hot key to abort the operation 12 ALARM SIGNALS Message Cause Outputs P1 Room probe failure Compressor output according to par Con...

Page 4: ... 0 OdS Outputs delay at start up 0 255 min 0 0 AC Anti short cycle delay 0 50 min 1 0 COn Compressor ON time with faulty probe 0 255 min 30 0 CH Kind of action CL cooling Ht heating CL Ht CF Temperature measurement unit C F C F C F rES Resolution in integer dE dec point dE dE ALc Temperat alarms configuration rE related to set Ab absolute Ab Ab ALU MAXIMUM temperature alarm Set 110 0 C Set 230 F 1...

Reviews: