Bolt material selection
(continued)
Table 6-2:
Bolt material selection
Description
ASTM SA 453 Grade 660
High temperature stainless steel
Selection of flange stud bolts and nuts
•
Select all fasteners (nuts and studs) used in a hydrostatic test according to the flange
size and quantity listed in ASME ANSI B16.5.
•
Use the shortest stud bolt that permits full engagement of the thread through the
nut by hand-tightening.
•
Use only clean, rust-free nuts and stud bolts.
Important
Ensure that once the nut is tightened, two threads outside the nut are exposed. The only exception is
when a flange requires hydraulic bolt tensioning. The manufacturer of the hydraulic bolt tensioning
equipment will specify number of exposed threads outside the nut.
•
Do not use damaged or worn stud bolts or nuts.
•
Do not use nuts or stud bolts that do not fit correctly together.
•
Do not use nuts or stud bolts without grade or type identification.
•
Do not mix nuts or stud bolts of different coatings. Different nut and stud bolt
coatings require different torques to achieve the same bolt tension.
•
Do not assemble nuts with the identification hard stamp against the back face of the
flange
Flange stud bolt and nut storage
Remove each nut and bolt as a pair. Thread the matching nut back onto the bolt. Stack
them in a fashion that will not cause thread damage.
Reuse of flange stud bolts and nuts
Daniel Quality Control permits the reuse of threaded fasteners under the following
conditions:
•
Fasteners are clean, free of corrosion, paint, thread damage, cracks, teeth marks
(caused by wrenches) or other signs of damage.
•
Fasteners are not tightened to or beyond their yield strength.
•
Fasteners have not lost their coating.
Compare the threads of a used stud bolt with the thread of a new stud bolt. Finger-tighten
the nut over the entire length of the bolt.
6.3
Assemble the electronic components
Follow the procedure below to install the LME and/or the RME electronics.
Installation procedure
60
Daniel Series 1500 Liquid Turbine Meter, NPS 3-24
Summary of Contents for daniel 1500 series
Page 8: ......
Page 12: ...Plan 2 Daniel Series 1500 Liquid Turbine Meter NPS 3 24 ...
Page 64: ...Prepare the turbine meter for use 54 Daniel Series 1500 Liquid Turbine Meter NPS 3 24 ...
Page 66: ...Install 56 Daniel Series 1500 Liquid Turbine Meter NPS 3 24 ...
Page 72: ...Installation procedure 62 Daniel Series 1500 Liquid Turbine Meter NPS 3 24 ...
Page 74: ...Testing 64 Daniel Series 1500 Liquid Turbine Meter NPS 3 24 ...
Page 75: ...Part III Operate Operate User manual 65 ...
Page 76: ...Operate 66 Daniel Series 1500 Liquid Turbine Meter NPS 3 24 ...
Page 80: ...Maintain 70 Daniel Series 1500 Liquid Turbine Meter NPS 3 24 ...
Page 101: ...Decommission the turbine meter User manual 91 ...
Page 102: ...Decommission the turbine meter 92 Daniel Series 1500 Liquid Turbine Meter NPS 3 24 ...
Page 103: ...Decommission the turbine meter User manual 93 ...