Important
A spool piece installed in place of the turbine meter is recommended for this procedure.
NOTICE
Comply with local government regulations and company requirements.
Minimum clearances for installation, operation and
maintenance
Below is the approximate shipping dimensions and weight for the Series 1500 LTM NPS
3-24. Consult the factory for certified dimension prints.
Dimensions for the Series 1500 LTM NPS 3-24
Figure 2-3:
Flow meter and flow straightening section dimensions for the Series
1500 LTM NPS 3-24
Table 2-11:
Size
A
B
C
Inches
mm
Inches
mm
Inches
mm
3
10
254.0
5
127.0
11
278.6
4
12
304.8
6
152.4
12
297.7
6
14
355.6
7
177.8
13
324.7
8
16
406.4
8
203.2
14
350.1
10
20
508.0
10
254.0
15
377.1
12
24
609.6
12
304.8
16
402.5
16
32
812.8
16
406.4
17
443.7
18
36
914.4
18
457.2
18
469.1
20
40
1016
20
508
19
494.5
24
48
1219
24
610
21
545.3
Operating conditions and specifications
User manual
37
Summary of Contents for daniel 1500 series
Page 8: ......
Page 12: ...Plan 2 Daniel Series 1500 Liquid Turbine Meter NPS 3 24 ...
Page 64: ...Prepare the turbine meter for use 54 Daniel Series 1500 Liquid Turbine Meter NPS 3 24 ...
Page 66: ...Install 56 Daniel Series 1500 Liquid Turbine Meter NPS 3 24 ...
Page 72: ...Installation procedure 62 Daniel Series 1500 Liquid Turbine Meter NPS 3 24 ...
Page 74: ...Testing 64 Daniel Series 1500 Liquid Turbine Meter NPS 3 24 ...
Page 75: ...Part III Operate Operate User manual 65 ...
Page 76: ...Operate 66 Daniel Series 1500 Liquid Turbine Meter NPS 3 24 ...
Page 80: ...Maintain 70 Daniel Series 1500 Liquid Turbine Meter NPS 3 24 ...
Page 101: ...Decommission the turbine meter User manual 91 ...
Page 102: ...Decommission the turbine meter 92 Daniel Series 1500 Liquid Turbine Meter NPS 3 24 ...
Page 103: ...Decommission the turbine meter User manual 93 ...