7
emersonfans.com
Please contact 1-800-654-3545 for further assistance
U.L. Model No.: CF1
10.
The fan comes with blue, black and white leads that
are 80” long. Before installing fan, measure up
approximately 6 to 9-inches above the ball/
downrod assembly. Cut off excess leads and strip
back insulation 1/2-inch from end of leads.
11.
Use five 10-32 x 3/8" pan head screws and flat
washers (supplied) to secure the flange to the
blade (Figure 7). Repeat for the remaining blade(s).
12.
Use the holes in the square recesses in the motor
hub marked with "4" and install the blade
assemblies in accordance with Steps 13 or 14.
13. FOUR-BLADE VERSION.
Attach one blade
assembly to the motor hub using two 10-32 x 5/8"
oval head screws (supplied) (Figure 8). Do not
tighten completely at this time. Install remaining
blade assemblies in the same way. Gently snug all
flange screws to the motor hub, working around the
hub in a clockwise sequence. Next, securely tighten
all flange screws, again working in a clockwise
sequence. Failure to follow this procedure could
result in fan wobble.
14. TWO-BLADE VERSION.
Attach one blade
assembly to the motor hub using four
10-32 x 5/8” oval head screws (supplied)
(Figure 9). Install the other blade assembly in the
same manner. Gently snug all flange screws to the
motor hub. Make sure the ends of the flanges are
engaged, then securely tighten all flange screws,
working in a clockwise sequence.
10-32 x 3/8"
PAN HEAD SCREW (5)
BLADE
FLAT WASHER (5)
BLADE
FLANGE
Figure 7
10-32 x 5/8"
OVAL HEAD SCREWS
(4 PER BLADE FLANGE)
20
°
TWO-BLADE
FLANGE
MOTOR HUB
Figure 9
10-32 x 5/8"
OVAL HEAD SCREWS
(2 PER BLADE FLANGE)
14
°
FOUR-BLADE
FLANGE
MOTOR HUB
Figure 8
Ceiling Fan Assembly
(continued)
To reduce the risk of personal injury, do not bend the
blade flanges when installing the flanges, balancing
the blades or cleaning the fan. Do not insert foreign
objects between rotating fan blades.
WARNING
!