Emerson CF705BS04 Owner'S Manual Download Page 6

6

U.L. Model No.:  52-ANT

4. How to Hang Your Ceiling Fan

(continued)

AT LEAST

7'

CEILING

FLOOR

The outlet box and joist must be securely mounted and
capable of supporting at least 50 lbs. Use only a U.L.
outlet box listed as “Acceptable for Fan Support of
22.7 kg. (50 lbs.) or less”.

WARNING

!

To reduce the risk of fire, electric shock, or personal
injury, mount fan to outlet box marked “Acceptable for
Fan Support of 22.7 kg. (50 lbs.) or less”, and use
screws supplied with outlet box. Most outlet boxes
commonly used for support of light fixtures are not
acceptable for fan support and may need to be
replaced. Consult a qualified electrician if in doubt.

WARNING

!

The fan must be hung with at least 7' of clearance from
floor to blades (Figure 6).

WARNING

!

1.

Securely attach the hanger bracket to the outlet box
using the two screws supplied with the outlet box.
(Figure 7.)

2.

Carefully lift the fan and seat the hanger ball/
downrod assembly on the hanger bracket that was
just attached to the outlet box (Figure 8). Be sure the
groove in the ball is lined up with tab on the hanger
bracket (Figure 7).

Figure 6

Hanger bracket must seat firmly against outlet box. If
the outlet box is recessed, remove wall board until
bracket contacts box. If bracket and/or outlet box are
not securely attached, the fan could wobble or fall.

WARNING

!

Failure to seat tab in groove could cause damage to
electrical wires and possible shock or fire hazard.

WARNING

!

To avoid possible fire or shock, do not pinch wires
between the hanger ball/downrod assembly and
hanger bracket.

WARNING

!

TWO SCREWS
SUPPLIED WITH
OUTLET BOX

HANGER
BRACKET

TAB

OUTLET
BOX

Figure 7

NOTE: CEILING COVER
OMITTED FOR CLARITY.

OUTLET
BOX

HANGER
BRACKET

HANGER BALL/
DOWNROD  
ASSEMBLY

NOTE: CEILING COVER, SUPPLY WIRES AND FAN WIRES OMITTED 
FOR CLARITY.

Figure 8

Summary of Contents for CF705BS04

Page 1: ... Model No 52 ANT Questions problems missing parts Before returning to the store call Emerson Electric Customer Service 8 a m 6 p m Eastern Monday Friday 1 800 654 3545 www emersonfans com CF705BS04 Brushed Steel CF705ORB04 Oil Rubbed Bronze CF705SW04 Satin White CF705WW04 Appliance White Model Numbers Net Weight 16 5 Lbs ...

Page 2: ...of wiring your ceiling fan If you do not know enough about electrical wiring have your fan installed by a licensed electrician WARNING To reduce the risk of electrical shock this fan must be installed with an isolating wall control switch WARNING To avoid fire shock or injury do not use an Emerson or any other brand of control not specifically approved for this fan WARNING This product is designed...

Page 3: ...BLADES BLADE FLANGES CEILING COVER HANGER BALL DOWNROD ASSEMBLY 3 emersonfans com Please contact 1 800 654 3545 for further assistance U L Model No 52 ANT 1 Unpacking Instructions This product is designed to use only those parts supplied with this product and or any accessories designated specifically for use with this product by Emerson Electric Co Substitution of parts or accessories not designa...

Page 4: ...at the main fuse box at this time and remove the existing light fixture 4 U L Model No 52 ANT 3 Ceiling Fan Assembly 1 Pass the 42 motor leads through the opening in the ceiling cover Be sure the cover is oriented correctly Figure 1 2 Separate untwist and unkink the three motor leads Route the motor leads through the hanger ball downrod assembly 3 Loosen the two screws in the motor coupling Align ...

Page 5: ...s are tightened Repeat this procedure for the other four blade assemblies 9 The blade flanges have an interlocking feature that must be fully engaged before tightening the screws Make sure all the flanges are properly engaged and then tighten the flange screws If one of the flanges does not seat properly on the motor hub loosen the adjacent flange screws re engage and reseat the flanges then tight...

Page 6: ... using the two screws supplied with the outlet box Figure 7 2 Carefully lift the fan and seat the hanger ball downrod assembly on the hanger bracket that was just attached to the outlet box Figure 8 Be sure the groove in the ball is lined up with tab on the hanger bracket Figure 7 Figure 6 Hanger bracket must seat firmly against outlet box If the outlet box is recessed remove wall board until brac...

Page 7: ...f the outlet box is grounded contact a licensed electrician for advice as it must be grounded for safe operation WARNING This product is designed to use only those parts supplied with this product and or any accessories designated specifically for use with this product by Emerson Electric Co Substitution of parts or accessories not designated for use with this product by Emerson Electric Co could ...

Page 8: ...ree cloth to avoid scratching the finish Abrasive cleaning agents are not required and should be avoided to prevent damage to finish 7 Maintenance Ceiling fan performance and energy savings rely heavily on the proper installation and use of the ceiling fan Here are a few tips to ensure quality and product performance Choosing the Appropriate Mounting Location Ceiling fans should be installed or mo...

Page 9: ...crews securing fan blade flanges to motor 2 Check to make sure the screws which attach the fan flanges to the are loose motor are tight 3 Wire connectors inside switch housing rattling 3 Check to make sure wire connectors in switch housing are not rattling against each other or against the interior wall of the switch housing WARNING Make sure main power is turned off 4 Motor noise caused by solid ...

Page 10: ...10 U L Model No 52 ANT 11 Repair Parts 18 10 9 16 17 15 13 12 8 7 6 4 5 1 2 3 11 14 ...

Page 11: ...ORB04 CF705BS04 Hanger Ball Assembly 761655 761655 92 761655 32 761655 17 Consisting of 1 Hanger Bracket 2 Hanger Ball 3 Downrod Parts Bag Containing 762897 3 762897 3 762897 762897 1 4 Wire Connector 3 5 Threaded Stud 2 7 Lockwasher 2 8 Knurled Knob 2 9 Pin Clevis 10 Clip Hairpin 12 Coupling Chain 13 Wood Pendant 14 Flange Screw with Lockwasher M6 x 14 1 17 Screw M5 x 6 Washer Head 16 6 Ceiling C...

Page 12: ...6511 to obtain a return authorization and service identification tag In order for us to confirm that your Emerson Ceiling Fan is still under warranty please retain your receipt or other proof of purchase and have that information readily available when returning your Emerson Ceiling Fan to your place of purchase or upon calling Emerson Customer Service If you call Emerson Customer Service prior to...