Emerson CF705BS04 Owner'S Manual Download Page 3

1.

Check to see that you have received the following
parts:

NOTE: If you are uncertain of part description, refer
to exploded view illustration.

a. Fan motor assembly
b. One switch housing assembly
c. Five fan blades
d. One ceiling cover
e. Five blade flanges
f. One hanger ball/downrod assembly
g. One hanger bracket
h. One loose parts bag containing:

1. Sixteen M5 x 6 washer head 

blade screws

2. One M6 x 14 flange screw

with lockwasher

3. One wood pendant
4. One coupling
5. Three wire connectors
6. Two threaded studs
7. Two lockwashers
8. Two knurled knobs
9. One clevis pin

10. One hairpin clip

NOTE: Place the parts from the loose parts bags in
a small container to keep them from being lost. If
any parts are missing, contact your local retailer or
catalog outlet for replacement before
proceeding.

2.

Remove the fan assembly from the protective plastic
bag. Place the fan assembly into the upper foam pad
with the top of the motor facing up.

The upper foam pad serves as a holder for the fan
during the first stages of assembly.

SWITCH CUP
ASSEMBLY

COUPLING
COVER

LOOSE PARTS
BAG

FAN MOTOR
ASSEMBLY

HANGER
BRACKET

FAN
BLADES

BLADE
FLANGES

CEILING
COVER

HANGER BALL/
DOWNROD
ASSEMBLY

3

emersonfans.com

Please contact 1-800-654-3545 for further assistance

U.L. Model No.:  52-ANT

1. Unpacking Instructions

This product is designed to use only those parts
supplied with this product and/or any accessories
designated specifically for use with this product by
Emerson Electric Co. Substitution of parts or
accessories not designated for use with this product
by Emerson Electric Co. could result in personal injury
or property damage.

WARNING

!

Do not install or use fan if any part is damaged or
missing. Call Toll-Free:

1-800-654-3545

WARNING

!

Before assembling your ceiling fan, refer to section on
proper method of wiring your fan (page 7). If you feel
you do not have enough wiring knowledge or
experience, have your fan installed by a licensed
electrician.

WARNING

!

This Manual Is Designed to Make it as Easy as Possible for You to Assemble, Install,

Operate and Maintain Your Ceiling Fan

Tools Needed for Assembly

One Phillips head screwdriver

One stepladder

One 5/16” blade screwdriver

One wire stripper

Materials

Wiring outlet box and box connectors must be of type
required by the local code. The minimum wire would be
a 3-conductor (2-wire with ground) of following size:

Installed Wire Length

Wire Size A.W.G.

Up to 50 ft.

14

50-100 ft.

12

Summary of Contents for CF705BS04

Page 1: ... Model No 52 ANT Questions problems missing parts Before returning to the store call Emerson Electric Customer Service 8 a m 6 p m Eastern Monday Friday 1 800 654 3545 www emersonfans com CF705BS04 Brushed Steel CF705ORB04 Oil Rubbed Bronze CF705SW04 Satin White CF705WW04 Appliance White Model Numbers Net Weight 16 5 Lbs ...

Page 2: ...of wiring your ceiling fan If you do not know enough about electrical wiring have your fan installed by a licensed electrician WARNING To reduce the risk of electrical shock this fan must be installed with an isolating wall control switch WARNING To avoid fire shock or injury do not use an Emerson or any other brand of control not specifically approved for this fan WARNING This product is designed...

Page 3: ...BLADES BLADE FLANGES CEILING COVER HANGER BALL DOWNROD ASSEMBLY 3 emersonfans com Please contact 1 800 654 3545 for further assistance U L Model No 52 ANT 1 Unpacking Instructions This product is designed to use only those parts supplied with this product and or any accessories designated specifically for use with this product by Emerson Electric Co Substitution of parts or accessories not designa...

Page 4: ...at the main fuse box at this time and remove the existing light fixture 4 U L Model No 52 ANT 3 Ceiling Fan Assembly 1 Pass the 42 motor leads through the opening in the ceiling cover Be sure the cover is oriented correctly Figure 1 2 Separate untwist and unkink the three motor leads Route the motor leads through the hanger ball downrod assembly 3 Loosen the two screws in the motor coupling Align ...

Page 5: ...s are tightened Repeat this procedure for the other four blade assemblies 9 The blade flanges have an interlocking feature that must be fully engaged before tightening the screws Make sure all the flanges are properly engaged and then tighten the flange screws If one of the flanges does not seat properly on the motor hub loosen the adjacent flange screws re engage and reseat the flanges then tight...

Page 6: ... using the two screws supplied with the outlet box Figure 7 2 Carefully lift the fan and seat the hanger ball downrod assembly on the hanger bracket that was just attached to the outlet box Figure 8 Be sure the groove in the ball is lined up with tab on the hanger bracket Figure 7 Figure 6 Hanger bracket must seat firmly against outlet box If the outlet box is recessed remove wall board until brac...

Page 7: ...f the outlet box is grounded contact a licensed electrician for advice as it must be grounded for safe operation WARNING This product is designed to use only those parts supplied with this product and or any accessories designated specifically for use with this product by Emerson Electric Co Substitution of parts or accessories not designated for use with this product by Emerson Electric Co could ...

Page 8: ...ree cloth to avoid scratching the finish Abrasive cleaning agents are not required and should be avoided to prevent damage to finish 7 Maintenance Ceiling fan performance and energy savings rely heavily on the proper installation and use of the ceiling fan Here are a few tips to ensure quality and product performance Choosing the Appropriate Mounting Location Ceiling fans should be installed or mo...

Page 9: ...crews securing fan blade flanges to motor 2 Check to make sure the screws which attach the fan flanges to the are loose motor are tight 3 Wire connectors inside switch housing rattling 3 Check to make sure wire connectors in switch housing are not rattling against each other or against the interior wall of the switch housing WARNING Make sure main power is turned off 4 Motor noise caused by solid ...

Page 10: ...10 U L Model No 52 ANT 11 Repair Parts 18 10 9 16 17 15 13 12 8 7 6 4 5 1 2 3 11 14 ...

Page 11: ...ORB04 CF705BS04 Hanger Ball Assembly 761655 761655 92 761655 32 761655 17 Consisting of 1 Hanger Bracket 2 Hanger Ball 3 Downrod Parts Bag Containing 762897 3 762897 3 762897 762897 1 4 Wire Connector 3 5 Threaded Stud 2 7 Lockwasher 2 8 Knurled Knob 2 9 Pin Clevis 10 Clip Hairpin 12 Coupling Chain 13 Wood Pendant 14 Flange Screw with Lockwasher M6 x 14 1 17 Screw M5 x 6 Washer Head 16 6 Ceiling C...

Page 12: ...6511 to obtain a return authorization and service identification tag In order for us to confirm that your Emerson Ceiling Fan is still under warranty please retain your receipt or other proof of purchase and have that information readily available when returning your Emerson Ceiling Fan to your place of purchase or upon calling Emerson Customer Service If you call Emerson Customer Service prior to...