4.2.1.2
Power Requirements
Make sure that the board is used in Centellis 2000 AdvancedTCA shelf. If the module is used in
a Centellis 2000 DC version shelf, make sure it is connected to -48 VDC up to -60 VDC (rated
voltage), according to Telecommunication Network Voltage (TNV-2).
A TNV-2 circuit is a circuit whose normal operating voltages exceed the limits for a safety-extra-
low-voltage (SELV) under normal operating conditions, and which is not subject to over
voltages from telecommunication networks.
On board voltages are 5.0 VDC, 3.3 VDC and 1.0 VDC:
z
5.0 V voltage is generated from the -48 V AdvancedTCA power by a DC/DC converter with
galvanic isolation suitable for TNV-2 circuits.
z
3.3 V and 1.0 V voltages are derived from the 5.0 V power.
Shock
Half-sine, 11 mSec, 30 m/Sec
2
Blade level packaging
Half-sine, 6 mSec at 180 m/Sec
2
Free fall
-
200 mm/all edges and corners
1.0 m (packaged) per ETSI 300 019-2-2
(Blade level packaging)
100 mm (unpackaged) per GR-63-CORE
Table 4-1 Environmental Requirements (continued)
Feature
Operating
Non-Operating (packed state)
Table 4-2 DC Board Power Requirements
Feature
Value
Rated Voltage
-48 VDC to -60 VDC
US and Canada: -48 VDC
Operating Voltage
-39 VDC to -72 VDC
US and Canada: -39 VDC to -60 VDC
Input current
0.2 A
Centellis 2000 User Card-10GE power
dissipation
3.8 W maximum
Summary of Contents for Centellis 2000
Page 6: ...Centellis 2000 User Card 10GE Installation and Use 6806800H33B 6 List of Tables ...
Page 8: ...Centellis 2000 User Card 10GE Installation and Use 6806800H33B 8 List of Figures ...
Page 22: ...Introduction Centellis 2000 User Card 10GE Installation and Use 6806800H33B 22 ...
Page 42: ...Board Exchange Centellis 2000 User Card 10GE Installation and Use 6806800H33B 42 ...
Page 55: ...Index Centellis 2000 User Card 10GE Installation and Use 6806800H33B 55 ...
Page 56: ...Index Centellis 2000 User Card 10GE Installation and Use 6806800H33B 56 ...
Page 57: ......