CASH

 TYPE A-401 CRYOGENIC PRESSURE REGULATOR

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

Emerson.com/FinalControl

© 2018 Emerson. All rights reserved.

VCIOM-10805-EN 20/08

DESCRIPTION

The Type A-401 regulator is a fully automatic 
pressure regulating valve designed for 
cryogenic service in the pressure build-up 
circuit. Because it may be used for either 
cryogenic liquids or gases, it may be installed 
either before or after the pressure build-up 
coil.

SPECIFICATION DATA

Service:

 Cryogenic liquids and gases 

(pressure reducing or pressure build-up 
service)

Sizes: 

½"

Connections:

 Threaded internal inlet 

and outlet.

Body Material:

 Bronze

Temperature Rating: 

-320°F (-195.5°C) to +150°F (65.5°C)

Maximum Initial Pressure:

 600 psig (41.4 bar)

INSTALLATION INSTRUCTIONS

The Type A-401 regulator should be installed in 
the horizontal position with the spring chamber 
upright or down. Install a Y-Type or equivalent 
strainer upstream of the Type A-401. For 
other installation requirements, consult the 
factory. For easy operation and maintenance, 
it is suggested that manual shut-off valves be 
installed upstream and downstream from the 
valve. Before installing the valve, the piping 
and valve should be thoroughly flushed out 
to remove any foreign material. In order to 
prevent contamination from entering the valve, 
an in-line screen is recommended. Install 
the valve with the inlet pipe fitted to the inlet 
connection identified on the valve body. Use a 
compatible sealant on the male pipe threads 
and do not over-tighten the valve connections.

CONSTRUCTION

See component description for materials of 
construction.

All parts are commercially cleaned for oxygen 
service. 

OPERATING INSTRUCTIONS

Adjusting the Delivery Pressure

The regulator’s delivery pressure setting is 
adjusted by turning the adjusting screw (1) 
at the top of the spring chamber (3) after 
loosening the adjusting screw lock nut (2). 
To increase the delivery pressure, turn the 
adjusting screw clockwise (into the spring 
chamber). To decrease the delivery pressure, 
turn the adjusting screw counter-clockwise (out 
of the spring chamber). Tighten the adjusting 
screw lock nut after the adjustment has been 
made (and reinstall optional cap).

MAINTENANCE INSTRUCTIONS

CAUTION

Before attempting to replace any spare parts, 
be sure to shut off all pressure connections to 
the valve. With the valve closed however, system 
pressure could still be locked between the shut 
off valve and the inlet and/or outlet sides of the 
regulator. Before proceeding with any valve 
service, be certain to relieve the pressure from 
both sides of the regulator.

After reassembly and before pressurizing the 
valve, tighten the adjusting screw to ensure there 
is force on the pressure plate. This will help avoid 
damage to parts that will cause the valve to leak 
and not function correctly.

Refer to section view on the following page for 
parts identification. Repair parts can easily be 
installed without removing the regulator from the 
line.