100-412-196 REV. 06
29
4.2
System Performance Benchmark
Each application and system configuration is slightly different. System performance will
vary when you change setup parameters and if your horn or tips change, and can affect
the results of your process. Creating a benchmark of your setup and performance can be
useful at a later date in identifying a change in performance, and can also help in
recreating your exact setup.
The following steps are used to record acceptable system performance, and part
acceptance.
Use the following steps to create and record a benchmark for your exact setup.
NOTICE
Make copies of the following page and keep it on file for future reference.
Table 4.6
System Performance Benchmark
Step
Action
1
Make a copy of the LPX Power Supply Setup Form provided on the following
page.
2
Identify your product type and the part of the product the process is being
applied to. Set up the LPX Power Supply (be ready to run), and prepare your
sample.
3
Record the serial numbers and horn information of the LPX Power Supply
unit, Horn, Converter, Portable Hand Tool, and any special equipment. Special
information about the Horns is etched into the horn.
4
Turn the LPX Power Supply system On.
5
Select Mode of operation. Set On time, Energy (Joules), and Off/Hold time.
6
Set your desired Amplitude.
7
Ready piece to be processed.
8
Initiate Start for ultrasonics On through the User I/O on the rear of the unit,
or through Hand Held.
9
Check part quality, and if necessary, change parameters and repeat process
until piece is satisfactory.
10
When satisfied with the welded part, observe% Power and record along with
other parameters on the LPX Power Supply Setup Form.
11
Note any special adjustments, settings, operating modes, or other system
variables that will be helpful at a later time in re-creating your setup.
12
Turn the system off.
13
Place the filled-in form in a safe place for future reference.
Summary of Contents for Branson LPX
Page 4: ...iv 100 412 196 REV 06 ...
Page 6: ...vi 100 412 196 REV 06 ...
Page 8: ...viii 100 412 196 REV 06 ...
Page 10: ...x 100 412 196 REV 06 Table 7 2 System Trouble Analysis Chart 73 Table 7 3 Alarms Errors 76 ...
Page 24: ...14 100 412 196 REV 06 ...
Page 33: ...100 412 196 REV 06 23 Chapter 3 Delivery and Handling 3 1 Delivery and Handling 24 ...
Page 38: ...28 100 412 196 REV 06 4 1 4 Declaration of Conformity Figure 4 1 Declaration of Conformity ...
Page 76: ...66 100 412 196 REV 06 ...
Page 85: ...100 412 196 REV 06 75 Figure 7 2 LPX Power Supply Interconnect Diagram ...