4.5.7 Power Supply Module Options DIP Switch
DIP switch changes the Seek and Start functions and can affect the Amplitude Control
functions.
There are two DIP switches that Branson uses interchangeably. The following Figures
illustrate each of them. Default operational settings are provided in the Tables.
Figure 4.14Type 1 DIP Switch Marked “OPEN” on Top of Switch, Default Settings.
CAUTION
General Warning
The components in the Power Supply section of the Integrated
Welder are subject to damage from electro-static discharge. When
working inside the Integrated Welder, use a grounded wrist strap and
minimize your movement to reduce the possibility of damage due to
static electricity.
WARNING
General Warning
Unplug the welder (if previously connected) and wait at least two (2)
minutes before opening the case. Hazardous Voltages exist and are
stored in the system.
NOTICE
Toggle 5 is not used
Table 4.5 Options for Setting the Type 1 Switch Select Block
Function
Option
Set Toggles
Seek
Seek on power up
–
Checks horn frequency upon
power up and stores it in memory.
1 – Down (Off)
1 – Up (On)
Auto Seek
–
Checks horn frequency once each
minute, timed from the last activation of
ultrasonics.
2 – Down (Off)
2 – Up (On)
100-214-251 IWoper.book Page 57 Friday, June 16, 2017 4:12 PM
Summary of Contents for Branson 2000 Series
Page 9: ...viii 100 214 251 REV 05 100 214 251 IWoper book Page viii Friday June 16 2017 4 12 PM ...
Page 47: ...38 100 214 251 REV 05 100 214 251 IWoper book Page 38 Friday June 16 2017 4 12 PM ...
Page 83: ...74 100 214 251 REV 05 100 214 251 IWoper book Page 74 Friday June 16 2017 4 12 PM ...
Page 89: ...80 100 214 251 REV 05 100 214 251 IWoper book Page 80 Friday June 16 2017 4 12 PM ...
Page 129: ...120 100 214 251 REV 05 100 214 251 IWoper book Page 120 Friday June 16 2017 4 12 PM ...
Page 135: ...126 100 214 251 REV 05 100 214 251 IWoper book Page 126 Friday June 16 2017 4 12 PM ...