29
Installation and Maintenance Instructions
MAN-02-04-99-0712-EN Rev. 1
February 2020
Actuator Configuration
Section 6: Actuator Configuration
Section 6: Actuator Configuration
Before connecting power to the actuator, check that the voltages are correct and
correspond to the indications on the nameplate. An incorrect power supply could cause
permanent damage to the electrical components.
Configuration of the SCE300 actuator can be conducted via the control panel inside the
actuator control system. To access the panel, remove the actuator cover and when the
configuration is complete, replace the cover by following the procedures indicated below.
When optional local control panel OM3 is installed and actuator configuration is conducted
via the pushbuttons on the logic board, the remote controls do not have to be energized.
6.1
Removal of the Control Unit Cover
To remove the control unit cover, follow the below instructions:
•
Using a 5 mm Allen key, loosen the four screws and remove the cover.
•
When setting the actuator parameters, do not operate the actuator remotely
or locally.
•
When removing the control unit cover, care should be taken to not damage the joint
surfaces of the cover.
•
If the screws of the cover must be replaced, SS Class A4 grade 80 screws must be used
with a minimum yield strength of 600N/mm² (87ksi).
•
Once the configuration is complete, reassemble the actuator cover.
CAUTION
Using fasteners other than the approved type may result in damage to the actuator or valve.
CAUTION
Failure to use the recommended bolts tightening torque can result in damage to the
actuator or valve.