28
October 2020
Installation, Operation and Maintenance Manual
VCIOM-15792-EN Rev. 0
Section 5: Maintenance
Maintenance
5.1.3
Lubrication of Actuator
For normal duty the Bettis GVO LP DA actuator is lubricated "for life".
In case of high load and high frequency of operation it may be necessary to periodically restore
lubrication: it is advisable to apply a generous coating of grease on the contact surfaces of
moving parts.
The following grease is used by Emerson for standard working temperature and suggested
for re-lubrication:
Producer
AGIP
Name
GR MU/EP2
NLGI grade
2
Worked preparation (dmm)
280
Drop point ASTM (°C)
185
ISO grade
X2
Equivalent oils:
ESSO BEACON EP2
BP GREASE LTX2
SHELL ALVANIA GREASE R2
ARAL ARALUB HL2
CHEVRON DURALITH GREASE EP2
CHEVRON SPHEEROL AP2
TEXACO MULTIFAK EP2
MOBILPLEX 47
PETROMIN GREASE EP2
For special working conditions and for working temperatures beyond the standard range
consult Emerson.