![Emerson AXP640-AC2-110VAC Installation & Use Manual Download Page 99](http://html.mh-extra.com/html/emerson/axp640-ac2-110vac/axp640-ac2-110vac_installation-and-use-manual_103182099.webp)
AXP640 Shelf Installation
AXP640 Installation and Use (6806800M24E)
99
5.11 Accessing the System
You can access your system using the SAM shelf manager. The SAM-1500 direct serial console
connector (front of chassis) is an RJ45 connector on the SAM face plate. This connector is
configured as DTE. Configure your console or terminal emulation software using the
parameters: baud rate 9600, data bits 8, parity None, stop bits 1, flow control None. The
system is shipped with a default password of root.
Matching cable (part number CABLE/RJ45/DSUB/6E) can be ordered by contacting your
Emerson sales representative. Refer to
for pin assignments.
5.12 Upgrading Firmware
Upgrading firmware on the AXP640 shelf involves the following components:
z
IPMC firmware on the three Fan Tray Modules (FTMs)
z
IPMC firmware on the two DC Power Entry Modules (PEMs)
z
Shelf Manager firmware (including an FPGA image) on the two SAMs
5.12.1 FTM IPMC Firmware Upgrade
There is a single IPMC firmware image common to the three FTMs in the AXP640. The FTM
IPMCs are assigned IPMB addresses 0x50, 0x52, and 0x54.
Different upgrade image variants are generated as part of the release, but only one file is
required for the normal field upgrade process. This file is
axp640_fantray-upgrade-
x_xx_xxx.hex
. As upgrades are released, Emerson will supply the current version of this file.
The upgrade process described here uses a script named ipmcUpgrade.sh, which is supplied
on shelf managers starting with build 5.3.1.-1.
Summary of Contents for AXP640-AC2-110VAC
Page 8: ...AXP640 Installation and Use 6806800M24E Contents 8 Contents Contents ...
Page 10: ...AXP640 Installation and Use 6806800M24E 10 List of Tables ...
Page 26: ...Platform Architecture AXP640 Installation and Use 6806800M24E 26 ...
Page 46: ...AXP640 Shelf Description AXP640 Installation and Use 6806800M24E 46 Figure 2 14 AC Inlet 220V ...
Page 52: ...AXP640 Shelf Description AXP640 Installation and Use 6806800M24E 52 ...
Page 76: ...Site Preparation AXP640 Installation and Use 6806800M24E 76 ...
Page 86: ...AXP640 Operations AXP640 Installation and Use 6806800M24E 86 ...
Page 110: ...AXP640 Shelf Installation AXP640 Installation and Use 6806800M24E 110 ...
Page 138: ...FRU Installation AXP640 Installation and Use 6806800M24E 138 ...
Page 189: ......