Supported IPMI Commands
ATCA-7368 Installation and Use (6806800M12C
)
128
7.5.8
Get Handle Switch Command
The Get Handle Switch command reads the state of the hot-swap handle of the IPMC.
Overriding of the handle switch state is allowed only if the IPMC operates in (manual)
standalone mode (for a description refer to
2:4
PPS IANA Private Enterprise ID
0x00400A = 16394 (Pigeon Point Systems)
LSB Byte first: byte 2 = 0A, byte 3 = 40, byte 4 = 00
Table 7-37 Set Hardware Address Command Description (continued)
Type Byte
Data
Field
Table 7-38 Get Handle Switch Command Description
Type Byte
Data
Field
Request Data
1:3
PPS IANA Private Enterprise ID
0x00400A = 16394 (Pigeon Point Systems)
LSB Byte first: byte 1 = 0A, byte 2 = 40, byte 3 = 00
4
FRU ID (specify as 0)
Response Data
1
Completion Code
2:4
PPS IANA Private Enterprise ID
0x00400A = 16394 (Pigeon Point Systems)
LSB Byte first: byte 2 = 0A, byte 3 = 40, byte 4 = 00
5
Handle Switch Status
0x00: The handle switch is open.
0x01: The handle switch is closed.
0x02: The handle switch state is read from hardware.