2.6
Configuration options
2.6.1
Measurement parameter units
The table below shows the measurement parameters and units that can be configured for
each parameter.
Table 2-1: Measurement parameter units
Parameter
Units
Acceleration
m/s
Velocity
m/s
mm/s
in/s
Temperature
°C
°F
Speed
rpm
Supply Voltage
V
2.6.2
Configuration defaults
Table 2-2: Configuration Values
Configuration option
Default value
Network ID
1234
Join Key
12340000 00000000 00000000 00000000
Message
WIRELESS VIBRATION TRANSMITTER
Description
ASSET NAME
Default Long Tag Format
VX WWYYTTTTTTT
Default Short Tag Format
VXAABBCC
Update Rate
60 minutes
Mounting Method
Not Set
Motor Type
Not Set
Line Frequency
Not Set
VFD
Not Set
Machine Noise Threshold
0.05 in/sec
Nameplate Speed RPM
0 rpm
Driver/Driven Ratio
1
X_YLOR
1600 lines
X_YFMIN
2 Hz
Configuration
User Guide
August 2020
MHM-97927-PBF
38
MHM-97927-PBF, Rev 1