Do not bolt one side at a time. Tighten each side simultaneously. Example:
1. Snug left
2. Snug right
3. Tighten left
4. Tighten right
Do not snug and tighten left and then snug and tighten right. Failure to do so
will result in liner damage.
Always check for leaks at the flanges after tightening the flange bolts. Failure
to use the correct flange bolt tightening methods can result in severe damage.
All flowtubes require a second torquing twenty-four hours after initial flange
bolt tightening.
Table 3-1. Flange Bolt Torque Specifications for
Rosemount 8705 and 8707 High-Signal Flowtubes
Teflon/Tefzel liner
Polyurethane liner
Size Code
Line Size
Class 150
(pound-feet)
Class 300
(pound-feet)
Class 150
(pound-feet)
Class 300
(pound-feet)
005
1
/
2
-inch (15 mm)
8
8
—
—
010
1 inch (25 mm)
8
12
—
—
015
1
1
/
2
inch (40 mm)
13
25
7
18
020
2 inch (50 mm)
19
17
14
11
030
3 inch (80 mm)
34
35
23
23
040
4 inch (100 mm)
26
50
17
32
060
6 inch (150mm)
45
50
30
37
080
8 inch (200 mm)
60
82
42
55
100
10 inch (250 mm)
55
80
40
70
120
12 inch (300 mm)
65
125
55
105
140
14 inch (350 mm)
85
110
70
95
160
16 inch (400 mm)
85
160
65
140
180
18 inch (450 mm)
120
170
95
150
200
20 inch (500 mm)
110
175
90
150
240
24 inch (600 mm)
165
280
140
250
300
30 inch (750 mm)
195
415
165
375
360
36 inch (900 mm)
280
575
245
525
See ”Safety Messages” on pages 3-1 and 3-2 for complete warning information.
Summary of Contents for 8700 Series
Page 2: ......
Page 4: ......
Page 12: ...Reference Manual 00809 0100 4793 Rev CA August 2004 1 4 Rosemount 8742C ...
Page 64: ...Reference Manual 00809 0100 4793 Rev CA August 2004 5 12 Rosemount 8742C ...
Page 102: ...Reference Manual 00809 0100 4793 Rev CA August 2004 Rosemount 8742C A 32 ...
Page 116: ...Reference Manual 00809 0100 4793 Rev CA August 2004 Rosemount 8742C B 14 ...
Page 135: ......