- 69 -
Maximum Velocity
MAXIMUM VELOCITY limits velocity entries to the value entered here.
Minimum Acceleration Rate and Minimum Deceleration Rate
Used to limit the minimum time it takes to accelerate and decelerate the motor and load
from zero to 3,000 RPM or vice-versa. This time is greatly affected by load inertia and
friction. Those factors should be considered when the time limits are set.
Distance Limit CW and Distance Limit CCW
Used to set the maximum distance that can be programmed in an index.
Position (Travel) Limit CW and Distance Limit CW
Used during absolute positioning applications. The limit positions are given with
reference to the home position. Because of this, a home cycle must be executed before
these travel limits are enabled.
Travel Limits/Fault Deceleration Rate
Used to set the deceleration rate after any fault occurs, or a travel limit (hardware or
software) is tripped.
Stop Deceleration Rate
Used as the deceleration rate for a stop command (Serial or I/O).
Feed Limit Distance
Used for feed sensor index applications. The user can limit the distance that the motor
will travel after it has been commanded to look for sensor input. This entry prevents
excessive travel if a feed sensor or switch fails.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com