- 53 -
In either mode the
±
10 VDC command signal is connected to the command input. The input
circuit of the drive is a differential input amplifier with the following characteristics.
Application of a + voltage to pin 7 with respect to pin 13 (GRD) will produce either a CW
motion or torque in the CW direction as viewed from the shaft end of the motor.
Figure 43
Command Input Circuit
IMPORTANT
: Voltages on pins 6 or 7 must not exceed
±
12 VDC with respect to analog
ground.
Figure 44
Command Connector
To execute the Analog Mode, the mode select switches must be set correctly for either Analog
Velocity or Analog Torque control and apply
±
10 volts DC to the command connector on the
amplifier.
REMINDER:
Both the hardware and software position travel limits are active if they are set
up.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com