Setting up a VPLEX Metro implementation
65
Setting up VPLEX
Task 10: Verify the
GeoSynchrony
version
Type the following command from the VPlexcli prompt, to display the software
versions:
version -a
In the output, confirm that the Product Version matches the required version in the
VPLEX release notes.
Task 11: Expose
back-end storage
1. From the VPlexcli prompt, type the following command to list all director port
WWNs (identified in the command output as addresses):
ll /engines/**/ports -p
2. Zone the storage to the port WWNs of the VPLEX back-end ports, following the
recommendations in the
Implementation and Planning Best Practices for EMC
VPLEX Technical Notes
, which are available on Powerlink.
Task 12: Resume
EZ-Setup
From the VPlexcli prompt, type the following command:
configuration continue-system-setup
Note that this part of the EZ-Setup finishes by rediscovering the back-end arrays.
Wait several minutes for the rediscovery to complete before you proceed to the next
task.
Task 13: Create a
meta-volume
1. From the VPlexcli prompt, type the following command to list available storage
volumes:
ll /clusters/cluster-2/storage-elements/storage-volumes -p
Output example (partial):
/clusters/cluster-1/storage-elements/storage-volumes:
Name
VPD83 ID
Capacity Use
Vendor
IO
Type
---------------
--------------------------------------- -------
-----
------
Status--------
Clar0068_LUN71
VPD83T3:6006016049e02100281ebe77852cdf11
78G
meta-data
DGC
alive
traditional
Clar0068_LUN74
VPD83T3:6006016049e02100291ebe77852cdf11
78G
meta-data
DGC
alive
traditional
Clar0068_LUN75
VPD83T3:6006016049e02100c064c78a852cdf11
10G
unclaimed
DGC
alive
normal
Clar0068_LUN76
VPD83T3:6006016049e02100c164c78a852cdf11
10G
unclaimed
DGC
alive
normal
Note:
EMC recommends that the meta-volume and mirror be on separate arrays.
From the
ll
output, identify the two back-end storage volumes (78 GB minimum)
to be used for the meta-volume and a mirror of the meta-volume.
Note:
If you do not see any available volumes:
a. Type the following commands to rediscover the back-end storage:
cd /clusters/cluster-2/storage-elements/storage-arrays
array re-discover
<array_name>
storage-volume summary
b. Type the following command to verify the availability of the provisioned storage:
Summary of Contents for VPLEX
Page 8: ...EMC VPLEX with GeoSynchrony 4 1 Installation and Setup Guide 8 Tables...
Page 20: ...EMC VPLEX with GeoSynchrony 4 1 Installation and Setup Guide 20 Introduction...
Page 76: ...EMC VPLEX with GeoSynchrony 4 1 Installation and Setup Guide 76 Setting up VPLEX...
Page 92: ...EMC VPLEX with GeoSynchrony 4 1 Installation and Setup Guide 92 Reference...
Page 94: ...EMC VPLEX with GeoSynchrony 4 1 Installation and Setup Guide 94 Index...