EMC VCE VxRail 120 Product Manual Download Page 33

4

Click a row to view more information about an event. 

New critical events are shown in red.

When you click an event, the red highlight is removed.

To set all critical events as "read", click 

Mark All as Read

.

5

If a physical component is listed in the 

Component

 column, click its 

Component ID

 in the Event

Details to view its status on the 

Health > Physical

 screen.

6

To download a list of events, click 

Export all events

. An 

events.csv

 file is created and

downloaded by your browser.

Monitoring logical system health

You can view the health of the nodes in your VxRail Appliance using the VxRail Manager 

Health >

Logical

 tab. This screen displays CPU, memory, and storage usage for your entire cluster, individual

appliances, and individual nodes.

Administration

VCE VxRail

 Appliance 3.5 Product Guide

33

©

 2016 VCE Company, LLC.

All Rights Reserved.

Summary of Contents for VCE VxRail 120

Page 1: ...www vce com VCE VxRail Appliance 3 5 Product Guide Document revision 1 0 June 2016...

Page 2: ...n history Date Document revision Description of changes June 2016 1 0 Initial release of VxRail Manager v3 5 VCE VxRail Appliance 3 5 Product Guide Revision history 2 2016 VCE Company LLC All Rights R...

Page 3: ...al VxRail Appliance serial number 17 Network planning 19 Pre installation Site Checklist 19 10GbE switch networking 19 Network requirements 19 VxRail Appliance Network Configuration Table 20 Licensing...

Page 4: ...58 Mount a new VMFS datastore over iSCSI 58 Replacing hardware 60 Handling replaceable units 60 Avoiding electrostatic discharge ESD damage 60 Emergency procedures without an ESD kit 61 Hardware accli...

Page 5: ...nline Support account to get access to support and product resources for your VxRail Appliance If you already have an account register your VxRail Appliance to access the available resources For conve...

Page 6: ...pport resources Access support resources for your VxRail Appliance by doing any of the following Click the VxRail Manager Support tab Point your Web browser to emc com vxrailsupport or support emc com...

Page 7: ...re required Click VCE Download Center to access the technical documentation Cisco EMC VMware employee or VCE Partner partner vce com A valid username and password are required VCE employee sales vce c...

Page 8: ...ail Appliance The VCE VxRail Appliance includes the appliance hardware VxRail Manager EMC Secure Remote Services ESRS and access to qualified EMC software products Appliance hardware The VxRail Applia...

Page 9: ...minimum CPU and memory overhead Virtual SAN pools the VxRail Appliance s internal SSDs and HDDs on the ESXi hosts to present a single datastore for all hosts in the cluster Virtual SAN uses a highly...

Page 10: ...E5 2620 v3 12 cores per node 256 GB RAM RJ45 SFP VxRail 160F all flash nodes 2 Intel Xeon Processor E5 2630 v3 16 cores per node 256 GB RAM 512 GB RAM RJ45 SFP VxRail 200F all flash nodes 2 Intel Xeon...

Page 11: ...icy The following table lists the minimum number of nodes in a cluster required to support a given number of node failures Number of node failures to tolerate Number of replicas Minimum number of VxRa...

Page 12: ...ppliances in the cluster must be running VxRail Manager version 3 5 or higher First generation appliances sold under the VSPEX BLUE name can be in the same cluster with VxRail Appliances as long as th...

Page 13: ...ndant PSUs 2 1600 W high efficiency redundant PSUs AC line voltage 220V AC 50 60Hz 220V AC 50 60Hz 220V AC 50 60Hz Power consumption operating maximum 13347 KVA 1337 KVA 1486 KVA Heat dissipation 4561...

Page 14: ...40 F to 158 F Operating relative humidity 50 to 85 RH Non operating relative humidity 20 to 90 RH Storage time unpowered Recommendation Do not exceed 6 consecutive months of unpowered storage Applian...

Page 15: ...ode 3 disk drive group 4 Node 4 disk drive group 5 Node 1 front control panel 6 Node 2 front control panel 7 Node 3 front control panel 8 Node 4 front control panel 9 Product serial number tag PSNT Fi...

Page 16: ...ption 1 Power button with Status LED Blue On System power on Off System power off Amber Blinking DC off and fault Amber and Blue Blinking DC on and fault 2 ID button with LED Blue Blinking Identificat...

Page 17: ...healthy Amber Blinking Reports system health fault 3 Power button Press and hold more than four seconds to turn off node 4 ID LED Blue Blinking Identification activated from front control panel Off N...

Page 18: ...2 and 3 on the left side of the chassis 2 Pull out the blue tabbed tag located above drives 2 and 3 3 Locate the appliance serial number label on the pull out tag VCE VxRail Appliance 3 5 Product Guid...

Page 19: ...ster and the rest of your infrastructure It is crucial that your 10GbE switch be configured properly for the VxRail Appliance to work Work with your VCE EMC or partner representative to ensure your sw...

Page 20: ...E switch for use with your VxRail Appliance This table lists the network parameters that are configured during VxRail Appliance setup Use the table before setup to plan your configuration Work with yo...

Page 21: ...s for IP pool 192 168 10 1 ESXi ending address for IP pool 192 168 10 4 vCenter Server IP address 192 168 10 1 01 VxRail Appliance IP address 192 168 10 1 00 Subnet mask 255 255 255 0 Gateway 192 168...

Page 22: ...twork name and VLAN ID Sales 110 VM Network name and VLAN ID Marketing 120 Unlimited number Solutions Logging vRealize Log Insight hostname loginsight vRealize Log Insight IP address 192 168 10 1 02 S...

Page 23: ...their VCE EMC or partner representative to obtain their license Procedure 1 Locate your partner activation code PAC 2 Log into the activation portal and redeem your PAC to receive your license keys U...

Page 24: ...Codes page enter your PAC in the Activation Code box 4 Click Continue and follow the instructions You will receive an email containing the license key The license key must next be prepared for your Vx...

Page 25: ...nterprise Plus CPU license What to do next For additional information on how to manage existing vSphere license keys in order to meet the Bring Your Own vSphere Licensing VLP requirements work with yo...

Page 26: ...o assign the new license to a host click the Assets tab and then click Hosts 9 Select the host and click Assign License Shift click to select multiple hosts to license A pop up window shows all availa...

Page 27: ...s overall system health support community activity and event history Figure 6 VxRail Manager Dashboard screen Expansion Expansion shows the status additional nodes being added to your VxRail Appliance...

Page 28: ...community shows the most recent articles and other content from the online VxRail community Support Support shows status and links to support resources including Last Heartbeat The last time an EMC S...

Page 29: ...ice Request Navigates to eServices where you can open a service request View the Last Configuration Sent Displays the most recent VxRail Appliance configuration data sent using ESRS Connect Home ESRS...

Page 30: ...rt eServices directly from VxRail Manager Before you begin To use Support eServices you must have created an account To create an account visit support EMC com About this task The VxRail Manager lets...

Page 31: ...he most recent activity from the VxRail Series community forums Procedure 1 Click SUPPORT in VxRail Manager to navigate to the Support tab 2 Observe the VxRail Community list The most recent activity...

Page 32: ...ts detected the EVENTS icon displays the number of unread events in red in the navigation bar Figure 8 VxRail Manager Events screen Procedure 1 Click EVENTS to navigate to the VxRail Manager Events ta...

Page 33: ...w its status on the Health Physical screen 6 To download a list of events click Export all events An events csv file is created and downloaded by your browser Monitoring logical system health You can...

Page 34: ...orage IOPS CPU usage and memory usage indicates the following Red Over 85 used Yellow 75 to 85 used Green Less than 75 used 2 Click an appliance name to view information about that appliance 3 Scroll...

Page 35: ...t and status information Use the Health window Physical tab to view the following Appliances in the cluster View appliance status and information such as ID serial number and so on Individual applianc...

Page 36: ...t to view more details Click a Disk in the Front View to see disk status and information Click a Node in the Back View to see compute and network information Click a power supply in the Back View to s...

Page 37: ...played for that disk 5 If a status icon is displayed click it to view event details in the Health window Results The Disk Information panel lists disk status and information about the drive such as St...

Page 38: ...he action you want Turn On Disk Locator LED Indicator starts flashing the disk LED Turn Off Disk Locator LED Indicator stops flashing the disk LED Viewing physical node status View compute SATA DOM an...

Page 39: ...Network interface card NIC MAC addresses and status Switching a node chassis LED on and off Switch a node s chassis LED indicator on or off The chassis LED flashes to help locate the node appliance i...

Page 40: ...and information for the power supplies of any appliance disk in a cluster Procedure 1 In VxRail Manager click HEALTH The Health window is displayed 2 Click Physical The Physical tab is displayed 3 Cl...

Page 41: ...formation and settings for VxRail Manager including VxRail Manager version Linked Online Support account Log collection EMC Secure Remote Support ESRS Network offline mode Health monitoring suppressio...

Page 42: ...ndle Enable EMC Secure Remote Support Displays whether or not ESRS is enabled on your VxRail Appliance Configure Network Environment Settings Disable certain features in offline mode Suppress Cluster...

Page 43: ...Figure 10 VxRail Manager Configuration General screen Administration VCE VxRail Appliance 3 5 Product Guide 43 2016 VCE Company LLC All Rights Reserved...

Page 44: ...ing for online support Procedure 1 In VxRail Manager click CONFIGURATION The Configuration window is displayed 2 Click General The General tab is displayed 3 Click one of the following buttons Set Sup...

Page 45: ...The Configuration window is displayed 2 Click General The General tab is displayed 3 Verify the value of Your current ESRS status is Disabled ESRS is not activated Deployed ESRS has been installed bu...

Page 46: ...Setting Internet online offline mode Follow these steps to enable or disable your VxRail Appliance s connection to the Internet About this task Note Some VxRail Manager features are disabled when the...

Page 47: ...of the banner Running a complete system diagnostic Follow these steps to run a complete system diagnostic report for your VxRail Appliance Procedure 1 In VxRail Manager click CONFIGURATION The Configu...

Page 48: ...s the progress on the Shutdown precheck list 5 When the shutdown precheck process successfully completes click Shutdown A progress bar is displayed as the automated shut down process continues If the...

Page 49: ...of the VxRail Manager Configuration window displays information about the applications and add ons currently installed on your VxRail Appliance It also allows you to download updates for those compone...

Page 50: ...nstalled on your VxRail Appliance About this task When a new version of an application is available CONFIGURATION in the left navigation bar displays a highlighted number The Update button is also dis...

Page 51: ...l Manager click CONFIGURATION The Configuration window is displayed 2 Click Market The Market tab is displayed 3 Scroll the Available Applications for this Cluster list if necessary to view all the ap...

Page 52: ...status messages may be displayed for an application instance Downloading The application is currently downloading Pending The application is waiting until another application finishes downloading IP a...

Page 53: ...The Market tab is displayed 3 Scroll the Available Applications for this Cluster list to find the application you want Filter the application list using the filter at the top of the list if desired 4...

Page 54: ...e Web Client to configure NFS and iSCSI on the ESXi hosts in the VxRail Appliance cluster and to create NFS datastores and VMFS datastores over iSCSI on external arrays in the vCenter Server Appliance...

Page 55: ...the hosts in the VxRail Appliance cluster that will mount the datastore You can select any or all hosts in the cluster 12 In the Ready to complete window review your entries and then click Finish to...

Page 56: ...Create a distributed port group first Procedure 1 Log in to the vSphere Web Client as an authorized user 2 In the vSphere Web Client click the home icon and go to the Networking configuration page 3...

Page 57: ...to complete the VMkernel creation Results The newly added VMkernel adapter is displayed and the detail info is shown in the lower panel The network configuration for iSCSI on the host is finished Set...

Page 58: ...k the Rescan the iSCSI Software Adapter icon The warning message disappears and the iSCSI Target server is displayed in the lower panel 13 Click Static Discovery to show the full target name of the iS...

Page 59: ...on The datastore status changes to Normal 7 In the Storage tab check the connection status between the iSCSI datastore and the hosts Results After the VMFS over iSCSI datastore is created you can Prov...

Page 60: ...body discharges through the circuits If the air in the work area is very dry running a humidifier in the work area will help decrease the risk of ESD damage Follow the procedures below to prevent dama...

Page 61: ...nnel or surfaces until you have installed the unit When you remove a unit from the antistatic bag avoid touching any electronic components and circuits on it If you must move around the room or touch...

Page 62: ...nges in temperature and humidity that are likely to cause condensation to form on or in that system or component Do not exceed the shipping and storage temperature gradient of 45 F hr 25 C hr Unpackin...

Page 63: ...following steps Refer to the following sections for detailed instructions 1 To start the replacement procedure navigate to the VxRail Manager Health Physical screen 2 Click the drive you want to repla...

Page 64: ...g ESXi host into maintenance mode and then powers it off The host s locator LED is on and the other LEDs for the cluster are off The VMs running on the host are migrated to other hosts in the cluster...

Page 65: ...ront of the appliance The bezel is required for EMI compliance when the enclosure is powered up Procedure 1 If the bezel has a lock insert the key that shipped with your enclosure into the lock and tu...

Page 66: ...Disk drives may be removed while the system is operational but should be immediately replace by another disk drive or an empty disk drive tray Procedure 1 Press the disk drive tray release button 2 P...

Page 67: ...the replacement disk drive and place it on a clean static free surface 2 Align the disk drive tray with the disk drive bay slot 3 Insert the disk drive tray into the bay and push the tray in until it...

Page 68: ...ent disk drive shipped in re package the faulted disk drive and prepare the package for return shipping Installing the bezel Procedure 1 Align the bezel with the appliance 2 Gently push the bezel into...

Page 69: ...out of maintenance mode 4 When the success message is displayed click Finish to complete the process Replacing power supply units PSUs VxRail Manager helps you identify failed power supplies in your...

Page 70: ...View of the appliance are displayed 4 Click a PSU in the Back View The Power Supply Information panel is displayed for that node The failed PSU is highlighted in red in the Back View of the appliance...

Page 71: ...on 1 Power Supply Status LED Green Normal operation Amber blinking Power off fault Green blinking Power on standby mode Each of the four nodes have a node control panel at the front of the appliance C...

Page 72: ...ff Amber Blinking DC off and fault Amber and Blue Blinking DC on and fault 2 ID button with LED Blue Blinking Identification activated Off No identification Each node is equipped with a power button a...

Page 73: ...Blinking Reports system health fault 3 Power button Press and hold more that four seconds to turn off node 4 ID LED Blue Blinking Identification activated from front control panel Off No identificatio...

Page 74: ...and place it on a clean static free surface near the appliance 6 Align the replacement power supply unit with the slot in the appliance 7 Push the power supply unit into the slot until it clicks Ensur...

Page 75: ...the status indicator on the power supply unit indicates normal operation Identify a faulted power supply unit see page 70 11 Using the shipping materials that the replacement power supply unit shipped...

Page 76: ...Appliance to stop operating Use the BMC Web console and remote console solely for read only monitoring purposes About the VxRail Appliance BMC interface and RMM port Your VxRail Appliance offers a bas...

Page 77: ...Press and hold for more than 4 seconds to power off the motherboard 6 Mainboard status indicator Off normal Flashing amber BMC reports system health fault 7 Power indicator Off power is off Flashing b...

Page 78: ...urity is only assured by using a cipher strength encryption of 128 bit Some older browsers may not support strong 128 bit encryption To use the remote console KVM window of your managed server Java Ru...

Page 79: ...mple http 192 168 101 11 2 Log into the BMC Web console by entering the following username and password Username admin Password admin Figure 23 BMC Web console login screen Out of band management VCE...

Page 80: ...isplayed to download the Java Network Launch Protocol jviewer jnlp file This in turn downloads the standalone Java application implementing the remote console Both Microsoft Internet Explorer and Mozi...

Page 81: ...s to the Integrated BMC Web console The protocol used to run these connections is a unique KVM protocol and not HTTP or HTTPS This protocol uses ports 7578 for KVM 5120 for CDROM media redirection and...

Page 82: ...es all of the nodes in the appliance You must follow the proper procedure to gracefully shut down and start up the VxRail Appliance A hard power cycle through the BMC interface without interfacing wit...

Page 83: ...managing IT infrastructure VCE solutions are available through an extensive partner network and cover horizontal applications vertical industry offerings and application development environments allow...