ED-64M Director Operating Features
Figure 1-2
Out-of-Band Management
High-Availability
Pairs of critical FRUs installed in the director provide redundancy in
case a FRU fails. When an active FRU fails, the backup FRU takes
over operation automatically to maintain director and Fibre Channel
link operation. (This process is called failover.)
UPM cards do not automatically fail over and provide link operation after a
failure. Fiber optic cables from the failed UPM card must be disconnected
and reconnected to ports on a functional card to continue operation.
Standard redundancy is provided through these components:
◆
Power supplies
— The director contains two power supplies that
share the electrical operating load. If one power supply fails, the
other supply handles the full load. Separate receptacles at the rear
of the director provide facility input power to each supply. For
full redundancy, input power for each receptacle should come
from a different source.
E-Mail Server
Connectrix Manager Client Workstations
SNMP
Management
Station
Connectrix Manager Server
Running on
Connectrix Service Processor
Switch/Hub
10/100 Mb/s
Corporate LAN
Summary of Contents for Connectrix ED-64M
Page 4: ...Connectrix ED 64M User Guide iv...
Page 18: ...xviii Connectrix ED 64M User Guide Figures...
Page 26: ...xxvi Connectrix ED 64M User Guide Preface...
Page 30: ...xxx Connectrix ED 64M User Guide Warnings and Cautions...
Page 60: ...2 2 10 Connectrix ED 64M User Guide Operating the Director...
Page 86: ...3 3 26 Connectrix ED 64M User Guide Product Manager Overview...
Page 326: ...B B 8 Connectrix ED 64M User Guide Configuring Network Addresses...
Page 334: ...D D 6 Connectrix ED 64M User Guide Configuring Embedded Web Server Passwords...
Page 442: ...F F 4 Connectrix ED 64M User Guide Specifications...
Page 450: ...G G 8 Connectrix ED 64M User Guide Customer Support...