DATASHEET
Hatteland Technology AS | www.hattelandtechnology.com | Enterprise no: NO974533146
1/4
4 channel RS-422 / RS-485, NMEA / IEC COM Module
Manufacturer:
Hatteland Technology AS
Product:
4 channel RS-422 / RS-485 COM module
Typenumber:
PCA200828-1
Last Revised:
27 Apr 2022
Revision#:
04
The Hatteland Technology COM modules provide the system with quad independent COM channels. The module is attached to the
motherboard via standard USB interface. Application software access the COM channels as standard COM devices, i.e. in the normal case
is there no requirements for additional software development. This module will mainly be integrated, electrical and mechanical, in the final
products, such as; Series X G1/G2, Series E Panel Computers and selected Stand-alone Computers.
Description:
Internal USB to RS-485 / RS-422 isolated
• Features
- Independent channels (If card is replaced most OS will not change COM port number).
- Outputs are short circuits protected. Inputs are protected.
- Driver strength are approved.
- All channels is fully isolated, channel to channel and channel to chassis.
- Classified towards IEC61162-1 and IEC61162-2.
- Tested according to EN61162.
- NMEA-183 Compliant.
- All requirement for usage in ECDIS applications/systems is fulfilled.
• Absolute Max voltage applied to outputs
±15V
• Data Rate / Technical Data Output
- Outputs 230kbps (Theoretically 400kbps).
- ±15kV ESD protection on all RS-485 signals. (Human Body Model - HBM)
- Isolation rating = 1000V DC 60s, not intended for connection to live power nets.
• Transmitter enable mode
- Standard Mode is automatic.
- Standard Mode will accept send by RTS, but will in fact ignore RTS.
- Each channel have a overide jumper
*
which can be used to force the transmitter to
always be active. See below and next page for details.
• Cable Connector
Terminal Block 5-pin rows (MC 1,5/ 5-STF-3,81) (see illustration below)
• Recommended Cable Thickness
Minimum 22 AWG - Maximum 18 AWG
• Power Consumption
0,6824A @4 active channels, 9600 bit/s, 27Ω load
• Supported Operating Systems (OS)
Microsoft® Windows® 7 Professional/Ultimate (Eng, SP1),
Windows® 10 IoT Enterprise 2016 LTSB, Windows® 10 IoT Enterprise 2019 LTSC
Linux:
Generic support for Kernel 3.0.0.19 or newer
• Documentation and Drivers:
https://www.hattelandtechnology.com/hubfs/pdf/misc/doc102080-1_usb-com_module_configuration.pdf
Windows® Driver:
https://www.hattelandtechnology.com/drivers?key=19.8.13.57.X.X.X
Linux Driver:
https://www.ftdichip.com/Drivers/D2XX.htm
Note: Listed Operating Systems above are hardware/platform dependent. Please check datasheet for specific unit if OS is supported.
•
Test and certificate
Hatteland Technology standard,
(tested / type approved by the following classification societies): * = PENDING
IEC 60945 4th
(EN 60945:2002)*,
IACS E10*
,
DNV
- Det Norske Veritas* /
GL
- Germanischer Lloyd*,
LRS
- Lloyd’s Register of Shipping*,
ABS
- American Bureau of Shipping*,
BV
- Bureau Veritas*,
CCS
- China Classification Society*,
KR
- Korean Register of Shipping*,
ClassNK
- Nippon Kaiji Kyokai*,
EU RO MR
- Mutual Recognition*
Note: Product below for illustration only. Location of module and product size/design may differ. Connector/pinning remain the same.
Illustration and Pinning:
4 Ports (Virtual COM) identified in the Operating System (OS):
COMx (A), COMx (B), COMx (C), COMx (D)*
*
Configuration dependent, x = next available port number(s) OS.
RS-485 Half Duplex (2-wire, supports ECHO) Configuration:
Connect TX and RX pair-wise: TX- to RX-, TX+ to RX+.
*Note: The jumper for “force of transmitter” is open by factory default. For some custom
models this jumper is preset to closed (active), in that case unit has to be opened and jumper set to open to allow Half Duplex mode.
5-pin Terminal Block 3.81
Pinout Assignments
69
IND100241-13
Appendix
5-pin Digital Output Module
“Safety Signal Relay”
3 A
DIG
OUT
1 2 3 4 5
PIN 01 Out:
011
COM (Common
Center Terminal)
PIN 02 N/C
Not Connected
Not in use
PIN 03 Out:
014
NO (Normally Open)
PIN 04 N/C
Not Connected
Not in use
PIN 05 Out:
012
NC (Normally Closed)
4+4 pin CAN I/O Module, 2 channels
Type Number “HT 00254 OPT-A1”
3 A B
CAN1
CAN2
1 2 3 4
1 2 3 4
Pin 01 Can1 CAN L
Pin 02 Can1 CAN L
Pin 03 Can1 CAN H
Pin 04 Can1 CAN H
Pin 01 Can2 CAN L
Pin 02 Can2 CAN L
Pin 03 Can2 CAN H
Pin 04 Can2 CAN H
8-pin Digital Output / Input Module
“Solid State Relay”
3 A
DIG
OUT
DIG
IN
1 2 3 4
1 2 3 4
Pin 01 Out:
041
Out +
Pin 02 Out:
042
Out -
Pin 03 Out:
031
COM (Common Center
Terminal) *
Pin 04 Out:
032
NO (Normally Open)*
* IEC 60950 Compliant, 48VDC
Pin 01 In:
052
+24VDC
Pin 02 In:
053
GND (Ground)
Pin 03 In:
061
+24VDC
Pin 04 In:
062
+Input
10-pin Digital Output / Input & Serial Module
“Mechanical Relay &
COM (isolated RS-422/485)
”
3 A
XIG
OUT
SER
I/O
1 2 3 4 5
1 2 3 4 5
PIN 01 Out:
021
COM (Common Center
Terminal)
PIN 02 N/C
Not Connected / Not used
PIN 03 Out:
024
NO (Normally Open)
PIN 04 N/C
Not Connected / Not used
PIN 05 Out:
022
NC (Normally Closed)
PIN 01 In:
71
Rx+ (Receive Data +)
PIN 02 In:
72
Rx- (Receive Data -)
PIN 03 Out:
73
Tx+ (Transmit Data +)
PIN 04 Out:
74
Tx- (Transmit Data -)
PIN 05 GND:
75
SGnd (Signal Ground)
10+10 pin RS-422 / RS-485 NMEA Module
Type Number “PCA100293-1”
3 A B
6 7 8 9 10
1 2 3 4 5
6 7 8 9 10
1 2 3 4 5
PIN 01 TxD- Transmit Data Negative
PIN 02 TxD+ Transmit Data Positive
PIN 03 GND Isolated Ground
PIN 04 RxD- Receive Data Negative
PIN 05 RxD+ Receive Data Positive
PIN 06 TxD- Transmit Data Negative
PIN 07 TxD+ Transmit Data Positive
PIN 08 GND Isolated Ground
PIN 09 RxD- Receive Data Negative
PIN 10 RxD+ Receive Data Positive
RS-485 Half Duplex (2-wire) Confi guration:
Connect TX and RX pair-wise:
TX- to RX-, TX+ to RX+.
*Note: The jumper for “force of transmitter” is
open by factory default. For some custom
models this jumper is preset to closed (active),
in that case unit has to be opened and jumper
set to open to allow Half Duplex mode.
10-pin RS-422 / RS-485 Module
“RS-422/RS-485 SCOM Buzzer”
1 2 B
2 4 6 8 10
1 3 5 7 9
PIN 01* RxD+ Receive Data Positive
PIN 02 GND Ground
PIN 03* RxD- Receive Data Negative
PIN 04 +5V
+5V Out
PIN 05* TxD+ Transmit Data Positive
PIN 06 BUZ- Buzzer Control Negative
PIN 07* TxD- Transmit Data Negative
PIN 08 BUZ+ Buzzer Control Positive
PIN 09 GNDR
Ground 100Ω
PIN 10 GND Ground
*Pin 1,3,5,7 = RS-485 Full Duplex (4-wire)
*Pin 5,7 = RS-485 Half Duplex (2-wire)
Summary of Contents for Hatteland HT20 70 Series
Page 8: ...8 This page left intentionally blank...
Page 9: ...9 General...
Page 14: ...14 This page left intentionally blank...
Page 15: ...15 Installation...
Page 43: ...43 Specifications...
Page 46: ...46 This page left intentionally blank...
Page 47: ...47 Specifications Factory Options...
Page 58: ...58 This page left intentionally blank...
Page 59: ...59 Specifications Accessories...
Page 62: ...62 IND100129 239 Specifications VSDDPVGA340 HT DPM2VGAF A1 DisplayPort to VGA adapter...
Page 63: ...63 IND100129 255 Specifications RC3473 HT DPM2DVI DF A1 DisplayPort to DVI adapter...
Page 65: ...65 Technical Drawings...
Page 68: ...68 This page left intentionally blank...
Page 69: ...69 Technical Drawings Accessories...
Page 76: ...76 This page left intentionally blank...
Page 77: ...77 Appendixes...
Page 82: ...82 Appendix IND100077 227 BIOS Overview and functions BQ370 MH3 BIOS Step Ver 0 1...
Page 151: ...151 Appendix IND100077 24 User Notes...
Page 153: ...153 Revision History IND100077 249...
Page 154: ...Hatteland Technology AS www hattelandtechnology com Enterprise no NO974533146...