Emax HULK POWER HP15P004SS Operating Instructions Manual Download Page 11

11

HP15P004SS man v.171212

Air Compressor

Troubleshooting

Always inspect the compressor before use, and make sure it is in good working condition. Make sure all air 

vents are clear. Check the power cable to make sure it is intact and free from cracks, bare wires etc. Avoid 

using solvents when cleaning plastic parts, most plastics are susceptible to damage from the various types of 

commercial solvents.

Trouble

Possible Cause

Corrective Action

Compressor will not start

1. Blown fuse or circuit breaker 

tripped

1. Replace or reset fuse/circuit breaker

2. Loose electrical connections

2. Check wiring connnections

Low pressure

1. Restricted air filter

1. Replace air filter

2. Defective check valve

2. Replace check valve

3. Air leak in safety valve

3. Check valve by pulling on ring. If 

condition persists, replace valve

Safety valve releases

Defective pressure switch

Replace pressure switch

Pressure in tank falls

1. Air leaks at joints

1. Allow the compressor to build pres-

sure in the tank, to the max pressure if 

possible. Spray or brush soapy water 

on all air connections and look for bub-

bles. Tighten leaky connections. Do not 

over-tighten. 

2. If the problem continues, contact 

customer support for further advice.

Unloader valve leaks when 

pump is not running

Unloader valve seal defective

Allow air in the air tank out until all 

pressure is released. Remove the un-

loader valve plug and clean the valve 

seal. If damaged, replace seal and 

re-install.

Compressor stopped and will 

not re-start

1. Thermal overload protector has 

engaged due to motor overheat-

ing

1. Check that the main supplied 

voltage corresponds to the compres-

sor specifications. An inadequate 

extension cord (too thin or too long) 

can cause the motor to overheat due 

to voltage drop. Excessive use (over 

1 hour continuous) can cause motor 

overheating. Allow the motor to cool 

down.

2. Motor windings burn-out

Contact customer support

Motor does not start and 

makes a humming sound

Capacitor burn-out

Contact customer support

Motor does not start or starts 

slowly

Low voltage electrical supply to 

motor

Check that the main supplied voltage 

corresponds to the compressor speci-

fications.  

An inadequate extension cord (too thin 

or too long) can cause the motor to 

overheat due to voltage drop. 

Check power quality at outlet

Compressor runs noisily and 

metallic sounds are heard 

Compressor will not come to 

max pressure

Head gasket or reed valve dam-

aged. 

Stop the compressor and contact cus-

tomer support

Compressor doesn’t provide 

as much air as when new 

and/or cuts off after a much 

shorter time period.

1. Tank has reduced capacity due 

to water retention 

2. Pressure switch is out of adjust-

ment

1. Open drain valve to release water

 

2. Contact customer support

Pump unit does not stop 

when the tank reaches maxi-

mum working pressure.

Defective or pressure switch out 

of adjustment

Stop the compressor immediately (risk 

of explosion) and contact customer 

support

Summary of Contents for HULK POWER HP15P004SS

Page 1: ...ufactures products for safe operation However operators and maintenance per sons are responsible for maintaining safety All safety precautions are included to provide a guideline for minimizing the po...

Page 2: ...on 5 Area 5 Electrical Safety 6 Operation 6 Safety Rules 6 Air Tool Cautions 7 Power Source Connection 8 Power Requirements 8 Grounding Instructions 8 Connect to power source 8 Getting Started 8 Assem...

Page 3: ...make any adjustments to the safety valve Periodically pull the ring on the safety valve end to check that it is working WARNING properly 5 RESERVOIR AIR PRESSURE GAUGE Indicates pressure of compresse...

Page 4: ...avoided may result in minor or moderate injury 7 fig 2 6 4 DANGER WARNING CAUTION Notice indicates important information that if not followed may cause damage to equipment Read all manuals included w...

Page 5: ...and its controls comply with all applicable OSHA Federal State and local DANGER regulations codes and standards relating to personal protective equipment This includes respiratory protective equipmen...

Page 6: ...cord away from heat sharp edges or moving parts Check for damage and replace damaged cords immediately before connecting to power supply Damaged cords increase the risk of electric shock DANGER 13 Alw...

Page 7: ...r chemicals WARNING WARNING Air Tool Cautions 1 DO NOT use air tools that are rated below the maximum rating of the compressor Select air tools air hoses pipes valves filters and other fittings accord...

Page 8: ...a qualified electrician before proceeding Connect to power source Consult a qualified electrician for proper installation of receptacle at the source of power This tool must be grounded while in use...

Page 9: ...circuit breaker It is recommended that a qualified electrician verify the ACTUAL VOLTAGE at the receptacle into which the unit will be plugged and confirm that the receptacle is properly fused and gr...

Page 10: ...ning the drain valve fig 6 1 Place a catch basin under the valve to protect the surface from water damage Cold Weather Starting Temperatures below freezing 32 F 0 C cause the metal parts of your air c...

Page 11: ...e un loader valve plug and clean the valve seal If damaged replace seal and re install Compressor stopped and will not re start 1 Thermal overload protector has engaged due to motor overheat ing 1 Che...

Page 12: ...n 24 Crank 25 Bearing 26 Holding screw 27 Cheese head screw 28 Right crankcase 29 Leading out line guard circle 30 Motor screw 31 Screw 32 Gasket 33 Stator 34 Bolt No Description 35 Rotor 36 Bearing 3...

Page 13: ...13 HP15P004SS man v 171212 Air Compressor Schematic Drawing...

Page 14: ...nty does not apply to defects due directly or indirectly to misuse abuse negligence or accidents repairs or alterations and lack of maintenance HULK shall not be liable for death injuries to persons o...

Page 15: ...dant les op rateurs et les personnes charg es de l entretien sont responsables du maintien de la s curit Toutes les pr cautions de s curit sont incluses pour fournir une ligne directrice pour minimise...

Page 16: ...20 S curit lectrique 20 Op ration 21 R gles de s curit 21 Pr cautions sur l outil pneumatique 22 Alimentation de la source 22 Exigences d alimentation 22 Instructions de mise la terre 22 Raccordement...

Page 17: ...r en cas de compression excessive La soupape de s curit est pr r gl e en usine N essayez ATTENTION pas d effectuer des r glages sur la soupape de s curit Retirez p riodiquement la bague de l extr mit...

Page 18: ...conna tre et comprendre votre compresseur Ceci est pr vu pour la S CURIT et pour VITER LES PROBL MES D QUIPEMENT Pour aider comprendre cette information conservez ce qui suit AVIS 7 fig 2 6 4 Danger...

Page 19: ...le r servoir d air La rouille peut affaiblir le r servoir d air et provoquer des fuites ou des clats Si la rouille est d tect e remplacez le r servoir imm diatement 4 N essayez pas de r parer le r se...

Page 20: ...iques AVERTISSEMENT DANGER DANGER 2 Placez l appareil sur un circuit d di et assurez vous qu aucun autre quipement lectrique ne soit connect celui ci Le d faut de c blage sur un circuit ind pendant pe...

Page 21: ...ignition et NE JAMAIS permettre de fumer proximit 9 Arr tez le compresseur et d branchez l alimentation si une condition dangereuse survient ATTENTION 10 Portez un v tement ajust et confine les cheve...

Page 22: ...t s des tuyaux ne soient d connect s accidentellement 3 Retirez les cl s de r glage ou les cl s avant de mettre l outil sous tension Une cl ou une cl molette qui est attach e une partie mobile du comp...

Page 23: ...es aiguilles d une montre la main NE PAS serrer excessivement le filtre air 3 Assurez vous que la longueur courte du boyau flexible est ins r e dans le trou du bo tier du filtre air Cela augmente les...

Page 24: ...us que la rallonge est correctement c bl e et en bon tat lectrique La longueur maximale du cordon d extension doit tre de 15 m tres 50 pieds La taille minimale du fil de rallonge doit tre calibr e 12...

Page 25: ...tent et cela rend le d marrage plus difficile Pour aider le fig 8 1 11 11 5 8 10 compresseur d marrer par temps froid suivez ces conseils 1 Essayez de conserver le compresseur d air des temp ratures s...

Page 26: ...lles Serrez les connexions qui fui ent Ne pas trop serrer 2 Si le probl me persiste contactez le service la client le pour obtenir d autres conseils La soupape de d charge fuit lorsque la pompe ne fon...

Page 27: ...it pas autant d air que lorsqu il tait neuf et ou s arr te apr s une p riode de temps beaucoup plus courte 1 Le r servoir a une capacit r duite en raison de la r tention d eau 2 Le pressostat est hors...

Page 28: ...24 Vilebrequin 25 Roulement 26 Vis de fixation 27 Vis t te cylindrique 28 Boitier droit 29 Garde de sortie principale 30 Vis du moteur 31 Vis 32 Joint d tanch it 33 Stator 34 Boulon No Description 35...

Page 29: ...29 HP15P004SS man v 171212 HULK Power Dessin sch matique...

Page 30: ...caus s directement ou indirectement par une mauvaise utilisation un abus une n gligence ou des accidents des r parations ou des modifications et le manque de maintenance HULK ne sera pas responsable...

Page 31: ...31 HP15P004SS man v 171212 HULK Power...

Page 32: ...32 Compresseur air...

Reviews: