WINTERRISING

Backwash  the  filter  for  at  least  thirty  minutes  before 
closing  down  the  pool  for  winterising.  This  will  clean 
the filter bed thoroughly. 

1)  Drain  the  filter  tank  by  removing  the  drain  cap  at 

the  base  of  the  filter  tank.  Leave  the  cap  off 
during  winter.

2)  Set  the  control  valve  handle  between  the  RINSE 

and  FILTER.  This  will  lift  the  handle  and  help  with 
the  draining  process  by  allowing  air  to  enter  into 
the tank.

3)  Unscrew  the  pressure  gauge  from  the  control 

valve and store the gauge indoor.

4)  Drain  and  winterise  pump  according  to  pump 

instructions.

5)  Repairs  should  be  made  during  the  off-season 

when  the  best  service  is  available,    do  not  leave 
them until the next season.

TROUBLE SHOOTING

SAND ENTERING THE POOL

Sand  too  small;  Flow  too  high;  Sand  bed  calcified; 
Broken  Laterals;  Loose  centre-pipe;  Too  much  sand; 
Control  Valve  not  engaged;  Air  accumulation  in 
filter.

SAND OUT OF BACKWASH HOSE

Flow too high; Too much sand in tank.

INADEQUATE FILTERING

Dirt build up; improper sand; Sand bed is too low;

Algae  in  filter;  Excessive  dirt  in  pool;  Calcified  sand 
bed;  Heavy  swimmer  load;  Flow  rate  too  high  or  too 
low; Backwashing cycle too short; Backwash line too 
small.

SHORT FILTER CYCLE

Dirty  filter;  Improper  sand;  Sand  bed  is  low;  Algae  in 
filter;  Excessive  dirt  in  pool;  Calcified  sand  bed; 
heavy  swimmer  load;  Flow  rate  too  high  or  too  low; 
B a c k w a s h i n g  c y c l e  t o o  s h o r t ;  C h a n n e l s  l o w ; 
Backwash  adapter  in  wrong  location;  Channels  in 
sand.

FILTER LEAKS

Tank cracked; Drain plug not tight; Valve/Tank O'ring 
damaged.

CONTROL VALVE LEAKS

Handle  not  properly  engaged;  Valve/Tank  O'ring 
damaged;  Valve  cover  O'ring  damaged.  Pressure 
gauge O'ring damaged.

ABNORMAL LOSS OF POOL WATER

Leak  inside  Control  Valve;  Leakage  from  pool  or 
piping.

HIGH PRESSURE FILTER

Dirty filter; Calcified sand bed; Return lines too small.

LOW PRESSURE IN FILTER

Control Valve incorrectly set; Pump running too slow 
(plugged  or  clogged);  Air  leakage  into  pump 
suction.

NOTE:

  If  the  recommendation  in  this  manual  do  not 

solve  your  particular  problem(s),  please  contact 
your local dealer for service.

2-4

3-4

3 Pour  the  recommended  amount  of  sand  into  the 

tank,  making  sure  that  the  centre-pipe  remains 
centred and vertical.

4) Level the surface of the sand upon completion.
5) Remove the Sand Fill Cover.
6) Carefully remove all sand particles from the valve 

mounting surface.

7) Place the O-ring into the groove on the tank.
8)  Lower  the  Multiport  Control  Valve  carefully  into 

position  so  that  its  underside  engages  with  the 
centre-pipe.  Rotate  the  valve  until  the  inlet  is 
approximately in line with the pump.

9)  Place  the  clamp  set  around  the  tank  and  the 

valve. Secure using the screw provided.

10)  Firmly  tap  with  a  rubber  mallet  outside  of  the 

clamps as you tighten the screw.

11)  Tighten  the  screw  until  the  Multiport  Control 

Valve  is  properly  assembled  to  create  a  water 
tight seal. Do not over tighten.

START-UP PROCEDURE

1 Be  sure  the  correct  amount  of  filter  sand  media  is  in 

the  tank  and  all  connections  have  been  made  and 
are secure.

2

Turn the Control Valve handle to the “Backwash” position. 

Press the handle downward before turning.

3

Start the pump according to pump instruction manual 

(be sure all suction and return lines are open).

4

Once water flow is steady out the waste line, run the 
pump  for  at  least  2  minutes.  The  initial  backwashing 
of the filter is recommended to remove any impurities 
or fine sand particles in the sand media.

5

Turn  the  pump  off  and  set  the  control  valve  to  RINSE 
position.  Start  pump  and  operate  until  water  in  sight 
glass is clear about ½ to 1 minute. Turn pump off, set 
valve  to  FILTER  position  and  restart  pump.  Your  filter is 
now operating in the normal filter mode, filtering particles 
and dirt from the pool water.

6

Take  note  of  the  initial  pressure  gauge  reading  for 

future  reference.  Variation  may  occur  from  pool  to 
pool.

7

Adjust  pool  suction  and  return  valves  to  achieve 

desired  flow.  Check  system  and  filter  for  water  leaks 
and tighten connections, bolts, nuts as required.

NOTE:  During  the  initial  clean-up  of  the  pool  water,  it 
may  be  necessary  to  backwash  frequently  due  to  the 
unusually heavy initial dirt load in the water.

IMPORTANT: 

To  prevent  unnecessary  strain  on  piping 

system  and  control  valve,  always  turn  off  the  pump 
before changing the operation of the control valve. To 
prevent  damage  to  the  pump  and  filter  and  for  proper 
operation  of  the  system,  clean  pump  strainer  (basket) 
and skimmer basket(s) regularly.

MULTIPORT CONTROL VALVE FUNCTIONS:-

FILTER

  gives  downward  flow  through  the  filter  bed.  This 

position can also be used for vacuuming.

BACKWASH

  gives  upward  flow  through  the  filter  bed 

that removes the dirt from the sand and carries it to the 
waste.

WASTE

  is  for  pumping  water  from  the  pool.  It  allows  the 

flow  from  the  pump  to  bypass  the  filter  and  go  directly 
to  the  waste.  You  can  also  use  this  position  to  vacuum 
heavy concentration of debris.

RECIRCULATE

  bypasses  the  filter  to  circulate  water 

through the pool system.

RINSE

  gives  a  downward  flow  that  settles  the  filter  bed 

after backwashing and carries any remaining loose dirt 
to the waste.

CLOSED

  prevents  only  backflow  of  water  from  pool 

during pump maintenance.
To WINTERISE, set the control valve handle in the middle 
between  RINSE  and  FILTER.  This  will  allow  air  to  leave  or 
enter the tank to help priming and draining. Only to be 
used when the pump is off.

VACUUMING THE POOL

Light Soil: set the control valve to FILTER position. 
Heavy Soil: set the control valve to WASTE position.

12 Install  the  pressure  gauge  into  the  threaded 

opening on the Multiport Control Valve.

13)  Install  the  union  sets  and  the  backwash  union 

set.

14)  Connect  pump  to  the  control  valve  opening 

marked “PUMP”.

15)  Make  return  to  pool  pipe  connection  to 

control valve opening marked “RETURN”.

16)  Connect  the  waste  water  pipe  to  the  control 

valve opening marked “WASTE”.

17

To  prevent  water  leakage,  be  sure  all  pipe 

connections are tight.

18) Prior to starting the filtration process by turning 

on  the  pump,  we  highly  recommend  that  you 
read  through  the  pump  instruction  manual  to 
ensure proper installation and to avoid the risk 
of electric shock.

POOL CHEMISTRY GUIDELINES

SUGGESTED POOL CHEMISTRY LEVELS

ACTION REQUIRED TO CORRECT POOL CHEMISTRY

 (Cyanuric Acid)

TO RAISE

Add Soda Ash

Add Sodium Bicarbonate

Add Chlorine Chemical

Add Chlorine Chemical

Add Stabilizer

TO LOWER

Add Muriatic Acid or Sodium Bisulphate

Add Muriatic Acid

No action-chlorine will naturally dissipate

No action-chlorine will naturally dissipate

Dilution-partially  drain&refill  pool  with  water

that has not been treated with Cyanuric Acid.

FIGURE3.-

Clamp Installation

tap with a rubber 

mallet and tighten 

the screws.

TYPICAL INSTALLATION

Sand

Laterals

Inlet
(From pump)

Outlet
(To pool)

Drain

Waste
pipe

Pressure Gauge

SPECIFICATIONS

D

B

A

C

E

A(mm)

B(mm)

Turnover Capacity (In Gallons) - 10 Hour

Turnover Capacity (In Gallons) - 8 Hour

3

Max Flow Rate (m /h)

Max Flow Rate (LPM)

Effective Filtration Area (Sq Ft)

Turnover Capacity (In Gallons) - 12 Hour

C(mm)

D(mm)

E(mm)

MFV27A

All Sand Required (kg)

0.14

117

7.0

15840
19800
23760

40

816
695
625
195
425

0.20

167

10.0

22176
27720
33264

70

889
772
712
225
500

0.28

233

14.0

30202
33752
45302

125
980
860
800
280
600

0.36

240

14.4

41184
51480
61776

185

1081

963
903
300
675

0.47

313

18.8

47309
59136
70963

320

1126
1008

948
370
775

88012526

CODE

88012527 88012528 88012529

88012531

MFV24

MFV20

MFV17

MFV31A MFV31

0.36

300

18.0

42874
53592
64310

185

1133

976
910
300
675

0.47

392

23.5

52166
65208
78250

320

1178
1021

955
370
775

0.61

508

30.5

65261
81576
97871

430

1296
1139
1073

440
875

88012530

88012532 88012533

MFV27

MFV35

PH                                                    7.2 to 7.6

TOTAL ALKALINITY                       100 to 130 ppm

CHLORINE (UNSTABILIZED)         0.3 to 1.0 ppm

CHLORINE (STABILIZED)               1.0 to 3.0 ppm

CHLOR

NE STAB

LIZER              40 to 70 ppm

MODEL NO.

Reviews: