background image

INSTALLATION

WARNING

By-passes filter for circulating water to pool

Used after backwash to flush dirt from valve

Cleaning Filter by reversing the flow

By-passes filter, used for vacuuming to waste or lowering water level

CLOSED 

Shuts off all flow to filter or pool

RECIRCULATE

WASTE 

RINSE

BACKWASH 

FILTER 

Valve Position

Normal Filtration and Vacuuming

Function

VALVE REPLACEMENT PARTS

FILTER & PUMP COMBO

Installation & Operating Instruction

FSF350-6W / FSF400-6W / FSF450-6W
FSF500-6W / FSF650-6W

1-4

4-4

17 18

19 20

21

13

14

15

16

6

12

1

2
3

4

7

8
9

10

11

17

18

19

22

21

23

24

25

26

*  Install filtration system including pump,filter tank and multiport valve. 
*  The filter system should be installed as close as possibie to the swimming pool and preferably at a 
level  of 0.50 metres below the surface of the water in the swimming pool. Make sure there is 
drainage available  at the place where the filter is to be installed. 
*  PUMP
1) Only qualified,licensed personnel should install pump and wiring.
2) Electrical Contractors Please Note:All 220 volt 50Hz pump must be wired to the main power supply 

trough an approved and correctly rated contractor.

3) Allow for gate valve in suction piping. 
4) Pump suction and discharge connections have moulded in thread stops,do not try to screw pipe in

    beyond these stops.

*  FILTER TANK and MULTIPORT VALVE
1) Loading the sand media.Filter sand media is loaded through the top opening of the filter.
a) Loosen the plastic clamps from tank neck.
b) Cap internal pipe with plastic cap to prevent sand from entering it.
c) We recommend filling tank approximately 1/2 way with water to provide a cushion effect when the 

filter sand is poured in. This helps protect the under-drain laterals from excessive shock.

d) Carefully pour in correct amount and grade of filter sand.Be sure center pipe remains centered in 

opening.  Sand  surface  should  be  leveled  and  should  come  to  about  the  middle  of  the  filter 
tank.Remove plastic cap from internal pipe.

2) Assemble filter control valve to filter tank.
a) Insert filter control valve(with O'ring in place)into the tank neck,taking care that the center pipe slips 

into the hole in the bottom of the valve.

b) Place two plastic clamps around valve flange and tank neck and tighten just enough so that the valve 

mayBe rotated on tank for final positioning. 

c) Carefully screw pressure gauge(with O'ring in place)into tapped hole in valve body.Do not over-

tighten.

d)  Connect  pump  to  control  valve  opening  marked  PUMP  with  hose.After  connections  are 

made,tighten clamps with screwdrive,tapping around clamp with screwdrive handle to help seat 
valve flange clamp.

3) Make return to pool pipe connection to control valve opening marked RETURN and complete other 

necessary plumbing connections,suction lines to pump,waste,etc.

4) To prevent water leakage,be sure all pipe connections are tight.

THIS FILTER OPERATES   UNDER HIGH PRESSURE.  WHEN ANY PART OF THE CIRCULATING SYSTEM 

(e.g., CLAMP, PUMP, FILTER, VALVES, ETC.) IS SERVICED, AIR CAN ENTER THE SYSTEM AND 

BECOME PRESSURIZED . PRESSURIZED AIR CAN CAUSE THE LID OR VALVE TO BE BLOWN OFF 

WHICH CAN RESULT IN SEVERE INJURY, DEATH, OR PROPERTY DAMAGE.

TURN PUMP OFF BEFORE CHANGING VALVE POSITION.

TO PREVENT DAMAGE TO THE PUMP AND FOR PROPER OPERATION OF THE SYSTEM.CLEAN 

PUMP STRAINER AND SKIMMER BASKETS REGULARLY.

DO NOT UNSCREW SCREWS OF FLANGE CLAMP WHILE PUMP IS RUNNING. 

!

!
!

!

Item

Part

 

No.

Description

Qty

1

01013003

Handle

(

Big

)

1

2

03018008

Pin

 

for

 

Handle

1

3

01181001

Washer

 

for

 

Handle

1

4

89280107

M6×30

 

Screw

 

with

 

Nut

 

for

 

Standard

 

Lid

6

5

01013004

1

.

5

"

Top

 

Mount

 

Valve

 

Standard

 

Lid

 (

Black

)

1

6

02011002

O

-

Ring

 

for

 

1

.

5

Valve

 

Lid

1

7

01181002

Washer

 

for

 

Spring

1

8

03014001

Spring

 

for

 

1

.

5

Top

 

Mount

 

Valve

1

9

02011022

O

-

Ring

 

for

 

1

.

5

Valve

 

Rotor

2

10

01021001

1

.

5

Valve

 

Rotor

1

11

02311002

Spider

 

Gasket

1

12

01013007

1

.

5

"

Top

 

Mount

 

Valve

 

Bottom

 

Body

 

Clamp

(

black

)

1

13

01013011

1

.

5

Diffuser

1

14

02011001

O

-

Ring

 

for

 

Diffuser

1

15

01013012

1

.

5

"

Top

 

Mount

 

Valve

 

Over

 

Drain

 

Diffuser

1

16

02011134

O

-

Ring

1

17

02020013

O

-

Ring

 

for

 

1

.

5

"

Connector

3

18

01013015

1

.

5

"

Connector

 (

black

)

3

19

02011003

O

-

Ring

 

for

 

1

.

5

"

Union

3

20

01171153

1

.

5

"

Union

 (

A

/

E

)

2

21

01013017

1

.

5

"

Union

 

Nut

 (

black

)

3

22

01041002

1

.

5

"

Union

 

With

 

Sight

 

Glass

 (

short

)

1

23

01172026

1

.

5

"

Union

 

With

 

Sight

 

Glass

 

Holder

1

24

01111048

Connector

 

for

 

pressure

 

gauge

/

stopper

1

02011139

O

-

ring

1

25

89021703

Drain

 

Plug

 

with

 

O

-

ring

1

26

06011029

Oil

 

Pressure

 

Gauge

 

With

 

O

-

ring

 (

40Psi

)

1

EMFS16031401  

Reviews: