background image

The most advanced way
saving energy and water

ELECTRIC AND

DIGITAL CONTROLLED

WATER HEATERS

Revolutionary
 temperature
  control and
       limiter

Operating and Installation Instructions

HOTRUN-X

Summary of Contents for HOTRUN-X Series

Page 1: ...The most advanced way saving energy and water ELECTRIC AND DIGITAL CONTROLLED WATER HEATERS Revolutionary temperature control and limiter Operating and Installation Instructions HOTRUN X...

Page 2: ...ing instructions 4 Water connections 5 Electrical connection 6 Technical speci cations 7 Legionella cleaning cycle 7 Maintenance 7 Troubleshooting technical support 8 11 Terms of warranty 12 Flexible...

Page 3: ...installed in an area exposed to the risk of freezing Do not operate a HOTRUN in a dry state The electrical power should remain switched of until the HOTRUN is completely lled with water and all air i...

Page 4: ...heater allowing for enough space above and below the water heater to remove the cover after installation and for the cord to be connected to an isolator switch without tension on the power cord 2 Mark...

Page 5: ...ning out during installation is not covered by warranty 7 There is no need to install an overpressure relief valve or a pressure limiter 8 The HOTRUN X range water heaters can be programmed to any tem...

Page 6: ...y Installer programming separate instructions for the installer only 8 Select the kWatt power setting rst while the display shows standby The 2 digits show the kWatt setting for example 48 4 8kWatt Th...

Page 7: ...water heater A cycle will run for 10 minutes at a temperature of 65 C as per the current Australian Health Ministers Regulations and directions given to ELWA in every State of Australia ELWA can organ...

Page 8: ...dry Low ow delayed by 5 seconds after start up Leakage of electricity Temperature probe of water inlet is faulty Exceed 70 Temperature probe of water outlet is faulty Dry burn protection Low water ow...

Page 9: ...t aluminum heating element Relay Water inlet temperature sensor Thyristor Water outlet temperature sensor Terminal Block Over temperature protector Display screen UP DOWN ON OFF buttons Cold water inl...

Page 10: ...continuity over the safety switch terminals If there is no continuity over the contacts push the reset button on the safety switch Seek electrical assistance to check power supply on all phases and c...

Page 11: ...UN doesn t switch on The pressure is less than 60 kPa The pressure of water under gravity is 9 kPa per metre this equates to approximately 30 kPa per oor plus the height of the roof tank Cause Remove...

Page 12: ...does not amount to a major failure 1 The warranty claim is valid only on presenting an original invoice a copy of the certi cate of compliance when the unit was installed stating the date of purchase...

Page 13: ...on the water connections and that has damaged the copper pipes inside the water heater 9 If the unit was not installed by a licensed tradesperson 10 Damage to the unit through normal wear and tear 11...

Page 14: ...oducts in the future for various reasons Ref 01 2020 ELWAPty Ltd ELWA Energysavers Co Ltd ELWA BV Adelaide Australia Phone 61 0 8 8377 6666 www elwa com au Guangzhou China Phone 86 139 2386 0259 www e...