background image

1 NO contact not potential free 16 A/250 V AC, 
incandescent lamps 2300 Watt, ESL and LED 
up to 400 Watt. 116x56x46 mm (measure-
ments without plug), black. Suitable for 
both indoors and outdoors, IP44 (splash-
proof). Encrypted wireless, bidirectional 
wireless and repeater function are 
 switchable. Only 0.4 watt standby loss. 
Smart Home actuator.

Adapter for German Socket (Type F).  
With increased shock protection.
Supply and switching voltage 230 V.

Zero passage switching.

Bistable relay to prevent coil power loss and 
the associated heat generation in switched 
state.  
After plugging wait for short automatic syn-
chronization before the switched consumer 
is plugged. 
In case of failure of the supply voltage, the 
switching state is maintained.
The  recurrent supply voltage is disconnec-
ted in a definite sequence.

Manual ON/OFF: 

Tap the button on the front (< 1 s).  
The actuator switches on and the green LED 
comes on.  
Tap the button again (< 1 s). The actuator 
switches off and the green LED goes off. 
Die grüne LED zeigt im Betrieb den Schalt-
zustand an, die rote LED zeigt eingehende 
Funk-Steuerbefehle durch kurzes Aufblinken 
an. Die rote und die grüne LED begleiten zu-
dem den Einlernvorgang.
Up to 35 wireless universal pushbuttons, 
 wireless direction pushbuttons, wireless 
central control pushbuttons, wireless motion 
detectors, wireless smoke alarms or wireless 

Wireless outdoor socket switch actuator

FASSA-230V

GB

Temperature at mounting location:  
-20°C up to +50°C.  
Storage temperature: -25°C up to +70°C. 
Relative humidity:  
annual average value <75%.

30 100 011 - 

1

window/door contatcs can be taught in. 
If several wireless door/window contacts were 
taught in, they are interlinked. A monitor 
becomes active for window contacts with 
cyclical transmission. Each valid incoming 
data telegram starts a time of approx.  
35 minutes. If no telegrams are received, 
the actuator switches off automatically 
when this time expires.

Teaching-in sensors: 

Press the button on the front (> 2 s < 4 s). 
The actuator switches to teach-in mode 
and the red LED lights up permanently.

   

Universal pushbutton:

 Tap the button 

on the front once. The green LED flashes 
briefly once every 3 seconds. 

   

Direction pushbutton:

 Tap the button 

on the front twice. The green LED flashes 
briefly twice every 3 seconds. 

   A rocker is fully taught-in automatically. 

The side where the pushbutton is first 
pressed is defined as switch-on and the 
other side is then the switch-off side.

   

Central control pushbutton 'ON':

  

Tap the button on the front 3 times. 
The green LED flashes briefly 3 times 
every 3 seconds. 

 

 

 

Central control pushbutton 'OFF':

  

Tap the button on the front 4 times. 
The green LED flashes briefly 4 times 
every 3 seconds. 

 

 FTK, FTKB, FFKB

 (EEP D5-00-01), 

FFG7B

 

(EEP A5-14-09), 

FTKB-hg

 (EEP A5-14-0A), 

FFGB-hg

 (EEP A5-14-01, 03), 

FTKE, 

FB55, FB65, FBH55SB, FBH65SB

 (EEP 

A5-07-01), 

FRWB, FHMB

 (EEP A5-30-03), 

GFVS

 and 

rotary switch 

(EEP A5-38-08, 

confirmation telegrams are switched 
on automatically): Tap the button on the 
front 5 times. The green LED flashes 
briefly 5 times every 3 seconds. 

Now press the teach-in sensor or send 
a teach-in telegram.

 The green LED 

lights up for 2 seconds and goes out. 
The red LED remains on and teach-in 
mode remains active.
Now you can activate the actuator by 
tapping the button (1 to 5 times) to teach 
in another sensor.
Press the button (> 2 s) to end teach-in 
mode. Both LEDs go off.

If the button is not pressed for longer than 
1 minute, teach-in mode ends automati-
cally. Both LEDs go off and the actuator 
reverts to normal mode.

Teach in encrypted sensors:

 

Press the button on the front (> 4 s < 6 s). 
The actuator switches to teach-in mode 
and the red and green LEDs flash alter-
nately at the rate of 1 second.
Then activate sensor encryption. The 
red LED goes out. The green LED lights 
up for 2 seconds, goes out and reverts to 
normal mode.
Then teach in the encrypted sensor as 
described in 'Teach in sensors'.
If no sensor is taught in encrypted, 
 encryption mode ends automatically 
 after 1 minute. The two LEDs go off and 
the actuator is in normal mode.

Clear sensors: 

Press the button on the front (> 6 s). The 
actuator switches to clear mode and the 
red LED flashes rapidly.

   

Clear individual taught-in sensors:

  

Press the pushbutton you want to clear 
or send a teach-in telegram to a sensor 
you want to clear. The red LED lights 
up for 2 seconds and goes out. To pre-
vent further unintentional clearing, 
cancel clear mode after completing a 
clear operation and the device switches 
to normal mode.

 

 Clear memory completely:

 Press the 

button on the front again (> 6 s). The 
red LED goes out. All taught-in sensors 
are cleared, the repeater and the con-
firmation telegrams are switched off.

Press the button (> 2 s < 4) to end clear 
mode. Both LEDs go off.
If the button is not pressed for longer than 
1 minute, clear mode ends automatically. 
Both LEDs go off and the actuator reverts 
to normal mode.

Setting mode: 

Press and hold the button on the front and 
plug the actuator into the socket. After 
releasing the button, the green LED flashes 
briefly once every 2 seconds. 
Press the button (> 2 s). 

Confirmation 

 telegrams are switched on.

 The green 

LED lights up for 4 seconds to indicate 
the state and then goes out. 

(

)

fi

i

Reviews: