Technical data

RoHS compliant

Application with diaphragm gas meters BK..B

Enclosure: IP 65.
Maximum allowable operating pressure p

max

 (as 

overpressure): see index plate, 
base gas pressure p

b

: see index plate, 

operating pressure range (absolute) p

g

800 to 1600 mbar.
Life of battery for index: approx. 15 years.
Life of battery for communications module:  
approx. 5 years.

Ambient temperature of index: -25 to +55°C (for 

entire meter, see index plate).

Accuracy of the clock: 0.4 s/day at 20°C on the 

day of manufacture.

Temperature measurement accuracy on the day of 

manufacture:  

  ± 0.2°C in the range from -10 to +55°C. 
  ± 0.25°C in the range from -25 to -10°C.
Pressure measurement accuracy: ± 5 mbar on the 
day of manufacture.
Pulse value V

Imp

 for pulse tests via optical inter-

face:

Gas meter

Decimal 

place 

in display

Pulse 

value V

Imp

 

in dm

3

BK-G6 

3

1

BK-G10 – BK-G40

2

10

Communications module: GSM RF technology.
Data logger for past meter readings: 
up to 20 weeks in hourly intervals.
Optical interface: pursuant to EN 62056-21, 
Mode (E), Annex B.2.

Pulse output

Type of switch: open collector transistor, normally 

closed.
For switching voltage and current, see section 

“ATEX explosion protection” below.

Resolution: 1 pulse per 10 litres of base volume.
Maximum pulse frequency: 4 Hz.
Minimum pulse duration: 125 ms.

For further technical data on diaphragm gas meters 
BK, see:

“Operating instructions for diaphragm gas meters 

BK-G1.6 to BK-G25” 

http://docuthek.kromschroeder.com/doclib/main.ph
p?language=1&folderid=400041&by_class=2&by_
lang=-1

 “Instruction Manual, Industrial Diaphragm Gas Meters 

Type BK-G40 · BK-G65 · BK-G100 and Type BK-G40T 

· BK-G65T · BK-G100T” 

http://docuthek.kromschroeder.com/doclib/main.ph
p?language=1&folderid=400045&by_class=2&by_
lang=-1

ATEX explosion protection

The index EI3 is certified as an ATEX subassembly 

and is marked as follows: 

II 2 G Ex ib IIA T4 Gb
  =  Specific explosion protection mark

II   = Equipment group for “non-mining”
2G   = Equipment category 2 (zone 1) for gas
EX   = Symbol for electrical equipment  

  built according to European standards

ib   =  Type of ignition protection:

 

  i = intrinsically safe

 

  b = suitable for use in zone 1

IIA   =  Explosion group for gases

T4   =   Temperature class: maximum allowable 

surface temperature: 135°C

Gb =  Equipment protection level (zone 1)

The batteries and communications modules are 

certified as parts of the electronic index. Use only 
spare parts from Elster.

The electrical interfaces feature the following 

parameters:
Pulse output:

–   U

i

   = 26.6 V

–   I

i

   = 250 mA

– P

i

   = 414 mW

–   C

i

   = 0.012 µF

–   L

i

   = 0 mH

For further technical data on diaphragm gas 
meters BK, see:

“Operating instructions for diaphragm gas meters 

BK-G1.6 to BK-G25” 

→ 

http://docuthek.krom-

schroeder.com/doclib/main.php?language=1&folderi
d=400041&by_class=2&by_lang=-1

 “Instruction Manual, Industrial Diaphragm Gas 

Meters Type BK-G40 · BK-G65 · BK-G100 and 

Type BK-G40T · BK-G65T · BK-G100T” 

→ 

http://

docuthek.kromschroeder.com/doclib/main.php?
language=1&folderid=400045&by_class=2&by_
lang=-1

Disposal

Components, particularly batteries, are to be dis-
posed of separately.
On request, old units may be returned carriage 
paid to the manufacturer, see page 8 (Contact) 
in accordance with the relevant waste legislation 
 requirements.

Summary of Contents for themis plus

Page 1: ...ns may only be carried out by qualified gas technicians Electrical interventions may only be carried out by qualified electricians Conversion spare parts All technical changes are prohibited Only use OEM spare parts Transport On receipt of the product check that the delivery is complete see page 2 Part designations Report any transport damage immediately Storage Store the product in a dry place Am...

Page 2: ...for use in po tentially explosive atmospheres For the exact use zone see ATEX sticker on the diaphragm gas meter or see Operating instructions for diaphragm gas meters BK G1 6 to BK G25 http docuthek kromschroeder com doclib main php language 1 folderid 400041 by_ class 2 by_lang 1 Instruction Manual Industrial Diaphragm Gas Meters Type BK G40 BK G65 BK G100 and Type BK G40T BK G65T BK G100T http ...

Page 3: ...ally The Current meter reading main screen appears when switching on the index If you are in a different menu the display will automatically change back to the main screen when no user key has been pressed for 30 s and switches off after a further 30 s You can navigate from the main screen to the various menus such as Date and time UTC using the user keys Menu overview Current meter reading Genera...

Page 4: ...ss further information Here the active tariff program is displayed as are the date and time of activation Tariff information ID Green Spring Demo From 01 01 2000 06 00 By briefly pressing the selection key you can visualize the consumption data Consumption results F01 0 00m3 F02 0 00m3 F03 0 00m3 UES 0x0240000000000000 In lines F01 to F03 the current absolute gas consumption values of the relevant...

Page 5: ...it its pulses the pulses are buffered and will be transmitted afterwards when con sumption is low Pin assignment Pin 1 2 4 6 not connected Pin 3 output Pin 5 output 3 6 4 5 2 1 To connect the pulse output use a socket type IEC 60130 9 Assistance in the event of malfunction Fault Cause Remedy Possible faults and suggested solutions The symbol is displayed If the symbol appears next to a measured va...

Page 6: ...id 400041 by_class 2 by_ lang 1 Instruction Manual Industrial Diaphragm Gas Meters Type BK G40 BK G65 BK G100 and Type BK G40T BK G65T BK G100T http docuthek kromschroeder com doclib main ph p language 1 folderid 400045 by_class 2 by_ lang 1 ATEX explosion protection The index EI3 is certified as an ATEX subassembly and is marked as follows II 2 G Ex ib IIA T4 Gb Specific explosion protection mark...

Page 7: ...GB 7 D GB ...

Page 8: ...ng Limited Paton Drive Tollgate Business Park Beaconside Stafford ST16 3EF T 44 1785 275200 F 44 1785 275305 jeavons info gb elster com www elstermetering co uk Ireland Active Energy Control Ltd Unit 4 Clare Marts Quin Road Ennis Co Clare T 353 65 6840600 F 353 65 6840610 info aec ie www aec ie We reserve the right to make technical modifications in the interests of progress Contact ...

Reviews: