9
Technical Data
enCore FC1
Operating Instructions
Page 93 of 97
9.3 Outputs
MFA8 output
board
•
1 PhotoMos output (NC, max. 28.8 V, 120 mA) for
alarm/message signaling
•
3 PhotoMos outputs (NO, max. 28.8 V DC, 120 mA)
for alarm/message or pulse outputs of up to 25 Hz
•
4 analog outputs 0/4 … 20 mA for measurements
•
alarm/message and pulse outputs galvanically iso-
lated amongst each other, and outputs and system
•
analog outputs galvanically isolated amongst each
another, and analog outputs and system
Table 9: Output channels – technical specifications
9.4 Interfaces for Digital Communication
CPU
•
LAN interface (Ethernet 10/100-Mb)
•
2 serial interfaces,
supported standards: RS485/RS422/RS232
MSER4
•
4 serial interfaces, galvanically isolated amongst
each other, and interfaces and system
supported standards: RS485/RS422/RS232
ESER4
•
3 serial interfaces, galvanically isolated amongst
each other, and interfaces and system
supported standards: RS485/RS422/RS232
•
LAN interface (Ethernet 10/100-Mb)
MFE7
•
1 serial RS485 interface
USB port
•
USB interface for connecting a PC or laptop for
parameterization and service purposes
Table 10: Protocol interfaces – technical specifications