EK280
Application Manual
6
2
EK280 Operation and Display
2.1
Display configuration
2.1.1
"Main" main display
With the calibration lock open,
"Main"
on the
"Ctrl."
display tab allows you to select different views and contents
for the
"Main"
tab:
"
Main
"
Description
meas.
Displayed: Volume at base conditions, volume at measurement conditions,
pressure, temperature, compressibility and conversion factor with short descriptions
Meter reading format: 8 digits before and 3 digits after decimal point
volume short
Displayed: Volume at base conditions and volume at measurement conditions with
short descriptions and header
Meter reading format: 8 digits before and 3 digits after decimal point
volume long
Displayed: Volume at base conditions and volume at measurement conditions with
header but without short descriptions
Meter reading format: 9 digits before and 4 digits after decimal point
Volume, p,T,Q
Displayed: Volume at base conditions, volume at measurement conditions,
pressure, temperature, standard load and operational load with short descriptions
Meter reading format: 8 digits before and 3 digits after decimal point
List
Displayed: Volume at base conditions, volume at measurement conditions, total
number of DE1 inputs (initial number for connected Encoder), pressure,
temperature, conversion factor, compressibility, operational load, standard load,
date and time
Vb, Vo, meas.
The following are displayed: Volume at base conditions, meter reading of the gas
meter (Encoder), pressure, temperature, compressibility ratio factor and conversion
factor with short descriptions
Meter reading format: 8 digits before and 3 digits after decimal point
Vb,Vo,p,T,Q
The following are displayed: Volume at base conditions, meter reading of the gas
meter (Encoder), pressure, temperature, standard load and operational load with
short descriptions
Meter reading format: 8 digits before and 3 digits after decimal point
2.1.2
Setting the number of tabs
With the calibration lock open, on the "
Ctrl.
" display tab the
"Menu"
value allows you to select the number of
tabs displayed.
"
Menu
"
Description
2 registers
The
Main
and
Ctrl.
tabs will be displayed.
3 registers
The
Main
,
Cust.
and
Ctrl.
tabs will be displayed.
4 registers
The
Main
,
Cust.
,
Admin
and
Ctrl. tabs
will be displayed.
5 registers
All
Main
,
Cust.
,
Admin
,
Serv.
and
Ctrl.
tabs will be displayed.
-
This option is system-generated and is not intended for use. It works in the same
way as "
2 registers