EK280
Application Manual
41
6.5.3
Parameterization
Parameterization of the EK280 must be effected with the "enSuite" software, as this is the only way of setting
all necessary parameters.
The parameters to be set will be found under the following menu headings.
Using the EK280 keypad:
Serv.
Outputs
Output 2
Serv.
Outputs
Output 3
Using the enSuite software:
"
Parameterize online
"
"
Parameters
"
Outputs
Output 2
"
Parameterize online
"
"
Parameters
"
Outputs
Output 3
Important parameters:
Parameter
Abbreviation LIS address
Value
(examples)
Notes / meaning
Mode output 2
Md.O2
02:605
8
HF-pulses
Value to be output
Sc.O2
02:606
02:310_0
Qb
04:310_0
Qm
Lower adjustment value
Aj1.O2
02:622
0
"0" m3/h
Upper adjustment value
Aj2.O2
02:623
1800
"1800" m3/h
Lower output frequency
f1.O2
02:624
0
"0" Hz
Upper output frequency
f2.O2
02:625
500
"500" Hz
Output access
Seal.
02:60E
No
Without access restriction
6.5.4
Connection example
Example: EK280 in Ex-Zone1; Ex isolation of outputs through the FE260; Use of a frequency/current converter
type "TURCK
– IM21-14EX-CDTRI" (Elster Order No.: 04 015 163)
Always comply with the information in the Operating Instructions for the equipment listed and with the relevant
safety regulations.