Electrical Parameters
5
Page 24 of 38
Safety Instructions
UFM Series 6
Intrinsically Safe
Terminals
IS_opt_B1,
IS_opt_B3
Namur pulse input #1, with label “IS_opt_B1” and
“IS_opt_B3” circuit (terminals Z1+ and Z1-):
In type of protection intrinsic safety, with the following
maximum values:
Uo
= 9.1 V
Io
= 37 mA
Po
= 84 mW
Lo
= 10 mH
Co
= 0.5 μF
Terminals
IS_opt_B2,
IS_opt_B4
Namur pulse input #2, with label “IS_opt_B2” and
“IS_opt_B4” circuit (terminals Z2- and Z2+):
In type of protection intrinsic safety, with the following
maximum values:
Uo
= 9.1 V
Io
= 37 mA
Po
= 84 mW
Lo
= 10 mH
Co
= 0.5 μF
Table 2: Intrinsically Safe Parameters
Non- Intrinsically Safe
Terminals
TB1 1,2,3
Power supply connection (Um = 250V) pins:
3. +24VDC nom. (18 - 30 VDC, 20 W)
2. 0 V
1. Do not connect (
see Chapter
[p.16])
Terminals
TB2, TB3 and J4
Non-IS data circuits (Um = 250V)
TB2: DSL / Network connections
TB3: Output / Communication ports
J4: Ethernet
Table 3: Non - Intrinsically Safe Parameters