924KTE4.01 - KT
series humidifiers
05/2021
|9|
2. TECHNICAL DATA
2.1 Technical specifications
Description
M.U.
KT3
KT10-230 KT20-230 KT5
KT10
KT20
KT30
KT40
KT60
Steam production
Production capacity
kg/h
3
10
20
5
10
20
30
40
60
Maximum pressure
MPa
(mmH
2
O) 0.002 (200)
Pipe connection external
diameter
mm (in.) 40 (1.57)
Steam distribution
Number of linear distributors
that can be connected
---
1
1
2
1
1
1
1
2
2
Number of steam blowers that
can be connected
---
1
1
/
1
1
/
/
/
/
Electrical properties
Power consumption
kW
2.25
7.5
15
3.75
7.5
15
22.5
30
45
Power supply
Vac,Hz 230V,50Hz
400V,50Hz
Phases
Ph
1
3
3
2
3
3
3
3
3
Current per phase
A
10
19
38
9
11
22
32
43
65
Water properties
Inlet water quality
---
"5.2.1 CHARACTERISTICS OF WATER" ON PAGE 13
Inlet water conductivity
μS*cm
70…1250
Inlet water hardness
°f
5...50
Inlet water pressure
MPa/bar 0.2...1/2...10
Inlet water connection
---
3/4"GAS
Water drain external dimensions
mm (in.) 42 (1.65)
General characteristics
Dimensions
mm (in.) See
Weight
kg
15
25
15
25
Hydraulic unit IP protection
---
20
Regulation
Type of controller
---
Built-in
Command signal
---
Proportional(0-10V)orON-OFF
Compliance
CE certification
---
√