924KTE4.01 - KT
series humidifiers
05/2021
|28|
•
Waterstartsleakingfromtheboilerbecauseitisbrokenorcracked.
N.B.:
Thewaterinsidetheboileriselectricallychargedsowaterleakingfromtheboilerisdangerous.
DANGER
RISK OF ELECTRIC SHOCK, EXPLOSION OR ELECTRIC ARC
•
Beforecarryingoutanyworkonthehumidifier,includinganykindofmaintenance,itmustbedisconnectedfromthepower
supply.
•
Ifwaterbeginsleakingfromtheboiler,disconnectthehumidifierimmediatelyfromthemains.
•
Ifanythingunusualorirregularhappenswhichisnotdescribedinthismanual,servicetheboilerand/orreplaceit.
Contact ELSTEAM Customer Service for advice and instructions;
DANGER
RISK OF ELECTRIC SHOCK, EXPLOSION OR ELECTRIC ARC
Ifanythingunusualorirregularhappens,disconnectthehumidifierimmediatelyfromthemains.
•
Afterextendedoperationand/orduetothewaterused,limescalecanbuildupinsidetheboiler,bringingtheelectrodes
closertogetherortothewallsoftheboiler.Theycanpotentiallybecomeelectricalconductorswhich,whenthereisno
waterintheboiler,cancausethetemperaturetorise(andthesurfaceoftheboilertobecomeblack)andtheboilerwall
tomelt(withelectricallychargedwaterleakingout);
DANGER
RISK OF ELECTRIC SHOCK, EXPLOSION OR ELECTRIC ARC
Ifwaterbeginsleakingfromtheboiler,disconnectthehumidifierimmediatelyfromthemains.
Checking the condition of the humidifier
Carry out the following controls as shown:
When...
What to do...
When starting
up
Checktherearenoleaksafteronehourofcontinuousoperation.
When changing
parts
Checktherearenoleaksafteronehourofcontinuousoperation.
Every 3 days
•
Checkthehumidifierisoperatingcorrectly(accordingtotheindicationsgiveninthismanual);
•
Checktherearenoleaksinthehydraulicsystem;
•
Checkeverythingappearstobeworkingproperly.
Every 30 days
•
Checktherearenoobstructionswhendischargingwater;
•
Checkthewaterdrainscorrectly;
• Remove any limescale in the drain.
Every 60 days
•
Checkthebuild-upoflimescaleinsidetheboilerisnotexcessive;
•
Washtheinsideoftheboilerwith20%aceticacid,cleaningtheelectrodesandthesurfaceoftheboiler.
•
Ifnecessary,replacetheelectrodesandseals.
Every 2 years
(*)
Replace the boiler.
Every 5 years
(**)
Replace the boiler.
(*) N.B.: If the humidifier is used continuously.
(**) N.B.: If the humidifier is used seasonally.
9.2 Periodical cleaning of the product and parts
•
Dischargewaterfromthehumidifier(see
"8.2 MANUAL WATER DISCHARGE" ON PAGE 26
• Turn off the power from the machine using the external disconnector;
•
Openthepanelsofthehumidifierasdescribed
•
Unscrewthetiethatblockstheinspectioncap;
•
Removetheplugandcleanthehumidifierofanylimescale;
•
Puttheinspectioncapandthetiebackinplace.
•
Unscrewthetwoscrewsonthetopofthehumidifieranddisconnectthesolenoidvalvethatfeedsthewater.