Display
Description
Defines whether the EMS controller uses a 1-day or a 7-day learning period.
Considerations
None
Range
00 (1 day) or 01 (7 days)
Global default
00 (1 day)
9.35
Display (dIS)
The table below details the display (
dI S
) parameter.
Display
Description
Defines whether the EMS controller displays the temperature
3.0
, or the word
US E
during the ready mode.
EMS controllers always display alarms.
Considerations
None
Range
00 (
US E
) or 01 (temperature)
Global default
01 (temperature)
9.36
Marketing mode (Ar)
The table below details the marketing mode (
Ar
) parameter.
Display
Description
Sets the cooler lights to remain on at all times for display purposes.
The coolers lights will remain on during
saving mode
.
Considerations
Does not affect saving temperature.
Only applies to the following controllers:
l
ems55
advanced
and ems55R
advanced
- GDC
l
ems55
advanced
and ems55R
advanced
- CO2
l
ems75sz (sub zero)
l
ems55sz (sub zero)
Range
00 (off) or 01 (on)
Global default
00 (off)
9.37
Defrost heater (dHr)
The table below details the defrost heater (
dHr
) parameter.