8.3
how to troubleshoot door alarms (door switch fitted)
Door open alarms are triggered if the cooler door is left open for longer than the time defined by the alarm delay (
Ad
) para-
meter.
If the door is closed, and a door open alarm is registered, this may indicate problems with the cooler door or the door
switch.
For information about the alarm delay
(Ad)
parameter:
l
See "alarm delay (Ad)" on page 67
Follow the chart to troubleshoot door open alarms on coolers with a door switch.
8.4
how to troubleshoot door alarms (no door switch fitted)
Door alarms with coolers without a door switch fitted usually indicates that the ems controller has an incorrect parameter
set.
For information about the alarm delay
(Ad)
parameter:
l
See "alarm delay (Ad)" on page 67
Follow the chart to troubleshoot door open alarms on coolers without a door switch fitted.
ems55advanced and ems55Radvanced / General Use