109
Automatic
CasaConnect KNX Control Center
• Version: 13.09.2021 • Technical changes and errors excepted.
6.3.7. Set movement limit (windows)
System > Set automatic > General settings > Movement limit
The movement limit determines that a window only opens partly when the outdoor
temperature is low. This prevents excessive cooling of the room.
"Movement limit" is then displayed on the start page.
7.4. Alarm and error messages > Window movement limit, Page 137
The degree to which the opening should be limited is set within the automation func-
tions for the different windows.
Colour restriction:
Shows the settings for the movement limit as soon as it has been set up. Tap the field
to apply the configuration.
Switch the movement limit
On
in order to set up and use for windows.
First specify the
outdoor temperature
below which the movement range of the win-
dows should be limited.
Default setting: 2.0°C.
Then set how many
hours
the outdoor temperature must be above the set outdoor
temperature so that the movement limit is raised again.
Default setting: 8 hours
6.3.8. Set wind delay (shades)
System > Set automatic > General settings > Wind delay
If the wind limit for a motor is exceeded, the wind alarm is triggered for 5 minutes. If
the wind value is exceeded again during this period, the waiting time of 5 minutes
starts again.
An additional delay after the wind alarm can be set for shades, during which the auto-
matic shade system is locked. This means the controls initially remain switched off af-
ter the wind alarm if the shade was in automatic mode before the wind alarm. Manual
operation is already possible again, however.
Wind delay:
Shows the duration of the wind delay. Touch the field to adjust the duration using a
slider.
Default setting: 0 minutes.
6.3.9. Specify automatic reset
System > Set automatic > General settings > Automatic reset