2

Description

Ventilation Unit WL610

 • Date of issue: 25.05.2011 • Technical changes reserved. Errors reserved.

1.

Description

The 

Ventilation Unit WL610

 is installed in the roof ridge area of conservatories in-

stead of the normal glazing. The 

WL610

 can be operated in air extraction and recircu-

lation modes. The recirculation mode may be used for heat gain and reduction of water
condensation thanks to an integrated temperature sensor in the ventilation unit. 

The 

WL610

 communicates wireless with the control systems WS1 Color, WS1000 Co-

lor and KNX WS1000 Color. The 

Ventilation Unit WL610

 may be operated directly

with the Remo 8 Remote Control.

Functions:

Air extraction mode

. Please pay attention to an adequate opening for supply 

air of approx. 12 240 mm² per WL610 (e. g. two Supply Air Units WFL or equal 
window opening) 

Recirculation mode for heat gain

: Warm air from the ridge is spread in the 

whole room 

Recirculation mode for reduction of condensation water

: The controls 

register critical conditions of temperature and dew point with the help of a 
special calculation method and start the ventilation unit in the mayor of cases 
even bevor humidity precipitates

Wireless control

 without additional device, only the power supply has to be 

connected 

Quiet lateral blower

Highly 

heat insulating housing

 consists of integral skin foam

Extremely 

tight closing flap

 (spur gear, worm drive) with self-locking drive 

and load limit switch

The 

installation pane

l is powder-coated on both sides and has an extremely 

high compressive strength

May be installed together with self-cleaning panes bacause of the silicon-free 
manufacture

The power and radio electronics are built inside, yet not in the way of the air 
current. Full maintenance from inside is possible

Manual operation with Remo 8 Remote Control possible (available separately)

1.0.1. Scope of delivery

Installation panel with ventilation unit and 10 m connection lead for voltage 
supply

1.1. Technical specifications

Mains voltage

230 VAC, 50 Hz

Length connectiong lead 
power supply

10 m 

Power consumption

Maximum: approx. 40 VA
Standby: 

approx. 2 VA

Summary of Contents for WL610

Page 1: ...er Elektronik GmbH Control and Automation Engineering Herdweg 7 D 75391 Gechingen Phone 49 0 70 56 93 97 0 info elsner elektronik de Germany Fax 49 0 70 56 93 97 20 www elsner elektronik de WL610 Ventilation Unit for air extraction and recirculation Interior view ...

Page 2: ...ation water The controls register critical conditions of temperature and dew point with the help of a special calculation method and start the ventilation unit in the mayor of cases even bevor humidity precipitates Wireless control without additional device only the power supply has to be connected Quiet lateral blower Highly heat insulating housing consists of integral skin foam Extremely tight c...

Page 3: ... the precise criteria Required opening for supply air 12 240 mm per WL610 e g two Supply Air Units WFL or equal window opening Sound pressure at 2 m distance max approx 58 6 dB A at full load U value insulating panel 1 03 W m K ventilator total approx 1 8 W m K calculated presup position area ventilator area panel Volumetric weight of insu lating panel 60 kg Compressive strength of panel 350 kPa M...

Page 4: ...red in side ouside Minimum width approx 840 mm Width of ventilator approx 698 mm plus 50 mm on both sides plus the size required on both sides for installation Minimum depth for shortening approx 580 mm Depth of ventilator approx 360 mm plus 100 mm at the top can not be trimmed plus 100 mm at the bottom plus the size required at the bottom for installation Minimum depth special panel approx 550 mm...

Page 5: ...only be carried out by a competent electrician Disconnect all lines to be assembled and take safety precautions against accidental switch on The device is exclusively intended for appropriate use With each inappropriate change or non observance of the instructions for use any warranty or guarantee claim will be void Level Flap Blower Extraction 8 opened runs highest speed Extraction 7 opened runs ...

Page 6: ...reg ulation and structural circumstances Avoid sources of interference and obstacles be tween receiver and transmitter that could disturb the wireless communication Those would be for example Walls and ceilings especially concrete Metal surfaces next to the wireless participants e g aluminium construction of a conservatory Other wireless devices and powerful local transmitters e g wireless headpho...

Page 7: ...e 25 05 2011 Technical changes reserved Errors reserved 2 4 Device construction Fig 2 1 Outlet cable voltage supply not visible when mounted 2 PCB 3 Ventilation unit with roll ventilator flap and drives 4 Screws M5 Allen 5 Screws M3 Allen 6 Inside cover hood 7 Lock hole ...

Page 8: ...y be detached No abra sive cleaning agents should be used for cleaning Maintenance and cleaning inside the device must only be car ried out by a competent electrician The device must be separat ed from power supply then e g deactivate or remove fuse Fig 3 Prited circuit board 1 Microfuse T 1 6 A 2 Terminals power supply L N PE 3 Terminals 1 Fan red 2 Fan blue 3 Fan black 4 Not in use 5 Flap drive ...