Elsema Eclipse MC240 Setup And Technical Information Download Page 1

www.elsema.com

MC240 for Double and Single Gate

Setup and Technical Information  
Includes latest Intelligent Technology

Double & Single Gate Controller

 

with Eclipse

® 

Operating System 

(EOS)

4th Edition

Eclipse

®

MC240

Summary of Contents for Eclipse MC240

Page 1: ...elsema com MC240 for Double and Single Gate Setup and Technical Information Includes latest Intelligent Technology Double Single Gate Controller with Eclipse Operating System EOS 4th Edition Eclipse M...

Page 2: ...ods purchased shall unless otherwise agreed in written pass to the buyer upon delivery of the goods Any figures or estimates given for performance of goods are based upon the company s experience and...

Page 3: ...18 Menu 6 Relay Output Modes Relay Output Modes 20 Menu 7 Special Features 23 Menu 8 Leaf Delay 24 Menu 9 Motor 1 Force and Overrun Time 25 Menu 10 Motor 2 Force and Overrun Time 25 Menu 11 Slow Speed...

Page 4: ...just the next generation but the Next Transformation in the gate and door industry creating an Eclipse over previously developed motor controllers This new intelligent motor controller is the best ma...

Page 5: ...MC240 MC240E 5 www elsema com...

Page 6: ...5 Lock Release Disables Auto Close 5 2 Relay Output 2 11 1 Open Slow Speed 11 2 Close Slow Speed 14 1 Enter Password 14 2 Delete Password 16 1 No of Motors 1 2 16 2 Reset Factory Default 3 1 PE Polari...

Page 7: ...C Only at Night 6 4 Service Call 2 4 PA Hold Gate 1 4 AC Only When Fully Open 1 6 EXIT 11 6 Disable Soft Start 14 3 EXIT 16 3 Test Inputs 16 4 Travel Timer 3 3 Stop Input Polarity 9 3 M1 Overrun Time...

Page 8: ...Supply DNS Day and Night Sensor Eclipse operating system Powered By ELSEMA FUSE Relay Relay Relay Relay Relay Stop Stop Code Reset 10 sec Antenna Antenna Shield Output 2 C Output 2 NC Output 2 NO Comm...

Page 9: ...d to connect an external push button to open the gate or door With this input gate or door cannot be closed Holding this input will prevent closing Normally Open input Close Only Used to connect an ex...

Page 10: ...y AC Supply Neutral Open AC Supply AC Supply Close Neutral Open Limit Common Motor 1 Close Limit Motor 1 Open Limit Motor 2 Close Limit Motor 2 Push Button Open Close Stop Common PED Access Photo Beam...

Page 11: ...wd Rev Close Rev Connecting Contactors Forward 24VAC Coil 24VAC Coil Reverse Normally Closed User can change AC Supply AC Supply Active Neutral Open Limit Common Motor 1 Close Limit Motor 1 Open Limit...

Page 12: ...mit Motor 1 Open Limit Motor 2 Close Limit Motor 2 FUSE Relay Relay Relay Relay Relay Common AC Supply Earth 240V AC Supply M Motor 1 Motor 2 M AC Supply Open AC Supply Close AC Supply Neutral Motor C...

Page 13: ...nu 13 to start i Learning or new control cards will automatically prompt you to do the i Learning 4 Look at the LCD and follow the instructions displayed 5 Buzzer will indicate learning was successful...

Page 14: ...e with Photoelectric Trigger Off 1 60 seconds 1 3 Auto Close after Power Restored Off 1 60 seconds 1 4 Auto Close Only when Fully Opened Off Off On 1 5 Auto Close Only at Night with DNS connected Off...

Page 15: ...he gate for a short time to allow someone to walk through the gate but does not allow a vehicle access Menu No Pedestrian Access Features Factory Default Adjustable 2 1 Pedestrian Access Travel Time 5...

Page 16: ...the gate will remain open in the Pedestrian Access position Open input Close input Push Button input and remote controls are disable Used in Fire Exit applications Menu 3 Input Functions This allows...

Page 17: ...4 2 Auxiliary Input Disabled Opens gate Closes gate Stops at Pedestrian Access Disables Auto Close 2nd Photoelectric Beam 4 3 Exit 2nd Photoelectric Beam can be configured to perform in the same way a...

Page 18: ...call strobe Warning light indicator or locking actuator Output 1 is a voltage free relay output with common normally open and normally closed contacts Factory default is lock brake release function Ou...

Page 19: ...ll when the service is due Strobe Warning Light when Opening or Closing The relay output is activated whenever the gates are operating The factory default is Off Either output 1 or output 2 can be cha...

Page 20: ...ctivation This sets the time the output is activated in the close direction Factory default is off Setting it to Hold means the output is activated for the total travel time in the close direction 6 1...

Page 21: ...nu 6 3 Strobe Warning Light Output Mode The relay output in the strobe Warning mode can be configured in different ways Menu No Strobe Warning Light Mode Factory Default Adjustable 6 3 1 Pre Open Stro...

Page 22: ...r Off Min 2000 to Max 50 000 6 4 2 Exit Menu 6 5 Locking Actuator Output Mode The time for which relay output 1 turns On before the gate starts to open and the time for which relay 2 turns On after th...

Page 23: ...Only By default the remote control allows the user to open and close the gate In public access areas user should only be able to open the gate and not worry about closing it Usually the Auto Close is...

Page 24: ...lso be necessary for special add on locking pins The control card has seperate leaf delay for the open and close directions When the control card is used with a single motor the leaf delay mode is dis...

Page 25: ...tor 1 Close Force 100 40 100 9 3 Motor 1 Overrun Time 10 seconds Off 30 seconds 9 4 Exit Menu 10 Motor 2 Force and Overrun Time This sets the force and the overrun time for motor 2 Menu No Motor 2 Obs...

Page 26: ...5 seconds 11 6 Soft Start Enabled Enable Disable 11 7 Exit 11 1 11 2 Open and Close Slow Speed This sets the speed at which the gate will travel in the slow speed region 11 3 11 4 Open and Close Slow...

Page 27: ...ation 12 3 and 12 4 Motor 2 Open and Close Anti Jam When the gate are in the fully open or fully closed position this feature applies a reverse voltage for a very short time It will prevent the motor...

Page 28: ...1 Event History The event history will store last 100 events The following events are recorded into the memory Power On All input activations Successful opening Successful closing Auto Close i Learni...

Page 29: ...and 2 can have separate open and close travel timers up to 120 seconds Used for Hydraulic Motors 16 5 Day and Night Sensor This option is only available when Day and Night Sensor DNS is connected It...

Page 30: ...mer PentaFOB Programmer Add edit and delete PentaFOB remotes from the receiver s memory The receiver can also be password protected from unauthorised access Booster for PentaFOB remotes Penta Repeater...

Page 31: ...remote in step 1 which activates the receiver 3 Press the button on the new remote which needs to be programmed for 2 seconds 4 Press the program button again of the remote in step 1 The receiver exit...

Page 32: ...ington Place Smithfield NSW 2164 Australia P 02 9609 4668 W www elsema com Sliding gate motor kits Sliding gate motor kits Swinging gate motor kits Swinging gate motor kits Motor control cards Kits Ke...

Reviews: