Dear user! 

Congratulations, you have acquired an ELMI shaker - product of advanced technology and 
high quality! 

DOS-20L shaker is easy to use and reliable in operation. We ask you to carefully read the user 

manual and observe all maintenance and operation requirements, as this will ensure long and 
flawless use of the device. 

 

The shaker is designed to mix up components in different kind of test tubes, flat bottom laboratory 
dishes, flasks, Petri dishes, etc. 

 

 

Technical specifications 

 

Size of working platform, mm 

415х295 

Speed of rotation,  RPM 

10-300 

Amplitude of platform movement, mm 

20 

Maximum load, kg 

Working  modes 

Type of platform movement 

orbital 

Timer 

 1 minute  

–  9 hours 59 minutes 

Environmental temperature, °C 

+4 up to +45 

Relative moisture of atmosphere (at 20°C temperature) 

not more than 80 % 

Voltage and frequency 

110-220 V, 50-60 Hz 

Power supply adapter: 

24VDC 

– 1A 

Maximal power consumption, W 

24 

Size of the  device, mm 

415х365x100 

Net  weight, kg 

8,8 

 

Delivery package 

 

Item 

Quantity 

Shaker ............................................................................................................................................ 1 
Power supply adapter ..................................................................................................................... 1 
Magnetic clips ................................................................................................................................ 8 
User manual ................................................................................................................................... 1 
Packaging ...................................................................................................................................... 1 

Summary of Contents for DOS-20L

Page 1: ...User manual Digital orbital shaker DOS 20L ELMI Ltd 21 133 Aizkraukles Str Riga LV 1006 Latvia T 371 67558743 T 371 67551934 E info elmi tech com W www elmi tech com...

Page 2: ...device 4 Control description 5 Using the device main menu 6 Orbital rotation mode 7 Auto reverse mode 7 Reciprocal mode 8 Vibration mode 8 Programming menu 9 10 Additional modes 11 Disinfection and cl...

Page 3: ...hes flasks Petri dishes etc Technical specifications Size of working platform mm 415 295 Speed of rotation RPM 10 300 Amplitude of platform movement mm 20 Maximum load kg 7 Working modes 4 Type of pla...

Page 4: ...ironments with aggressive or explosive chemical mixtures Do not operate the unit if it is faulty or been incorrectly installed For indoor use only Before using any cleaning or decontamination method e...

Page 5: ...4 1 Network switch 2 Power plug 3 Working platform 4 Casing 5 Control panel 3 4 1 2 5...

Page 6: ...ight navigation keys and increasing decreasing parameter value keys Entering and exiting key in programming mode to set the step parameter Start Stop key Setting key to manage the interface of device...

Page 7: ...Reciprocal 4 Vibration To choose a mode go to the lowest level of the main menu and select the desired mode using the right or left navigation keys Adjusting the parameters of the mode Using the navig...

Page 8: ...ters TIMER 1 minute 99 59 minutes continuous mode PRM 15 300 Auto reverse mode Auto reverse mode platform orbital motion mode with set and equal numbers of clockwise and counter clockwise turns Adjust...

Page 9: ...and operating time Options TIMER 1 minute 99 59 minutes continuos mode RPM 07 20 Angle 10 360 Vibration mode Vibration mode reciprocating type of movement of the platform imitating shake Ability to cu...

Page 10: ...ogramming menu Ranges are from 1 to 99 or continuos mode can be used Create a custom cycle program by adding four steps and a number of program repeat cycles as required All settings are made using th...

Page 11: ...tep menu s bottom line and select the pause mode set the time to 1 minute and press ENTER key 3 Select the 3rd step and press ENTER key 3 1 Go to the step menu s bottom line and select orbital rotatio...

Page 12: ...he PROGRAM key and switching the network switch off and on again To return to the advanced menu repeat the operation Interface adjustment menu In the interface menu you can adjust the display brightne...

Page 13: ...n 80 and temperature range of 10 C up to 40 C It is not recommended to store the equipment more than 36 month Warranty statements Warranty applies to 24 month period from the date of purchasing Malfun...

Page 14: ...ry for this class of device Quality control person name signature Date of manufacture Place for stamp Certificate of sale Organization Address Phone Vendor name signature Date of sale Manufacturers ad...

Page 15: ...14 Video instruction is available youtube com elmimedia videos ELMI Ltd 21 133 Aizkraukles Str Riga LV 1006 Latvia T 371 6755 8743 T 371 6755 1934 E info elmi tech com W www elmi tech com...

Reviews: