background image

e-mail[email protected]    internet: www.elmes.pl 

Elmes Elektronik 01.2015. All rights reserved

 

 

ONE RELAY OUTPUT REMOTE CONTROL SETS WITH 

DYNAMIC CODE:     U1HS,  U1HSD,  U1HSL,  U1HR 

This  manual  covers  the  following  remote  control  products  operation,  installation  and 
programming: 

Equipment 

Type 

Set Content 

Operating Range 

U1HS 

receiver U1HR + 2 transmitters UMB100HT 

100 m 

U1HSD 

receiver U1HSR + 2 transmitters DWB100HT 

100m 

U1HSL 

receiver U1HR + 1 transmitter AN200HT 

200 m 

U1HR 

U1HR 

– receiver only 

All above listed products include the same superhet receiver model featuring: 

 

One galvanic separated relay output with NC/NO terminals, 

 

One  OC  (open  collector)  transistor  type  signal  output  S  pulse  indicating  relay 
output switch-over,  

 

Two colour LED indicating state of the relay output, 

 

Highly sensitive and selective superhet receiver, 

 

Memory capacity of up to 112 keyfob remote control transmitters, 

 

KEELOQ

®

 dynamic encoding system. 

Receiver Operation Modes 

U1HR receiver allows various operation modes depending on selection made by jump-
ers  JP1 & JP2  and  programming  Monostable  (pulse)  or  Bistable  (on/off)  relay  output 
mode (step 2 and 3 of programming procedures), as shown in the Table below: 

Table of relay output available operation modes

 

Jumpers 

State 

Monostable Mode 

(1)

 

Bistable Mode 

(1)

 

JP2 On 

JP1 

(3)

 

 

A.

 

Pressing transmitter button sets receiver’s 

relay output on for programmed time period. 

Next pressing of the button, while output is 

on,  prolongs set on time of the output. 

B.

 Each pressing of remote 

transmitter button sets re-

ceiver relay output on and off 

alternately (on/off mode). 

JP2 Off, 
 JP1 On 

C.

 Receiver relay output is set on for as long 

as transmitter button is pressed and sets off, 

after short delay

(2)

 , on button release.  

Not available 

JP2 Off 

 JP1 Off 

D.

 Pressing transmitter button 1 sets the out-

put on. Pressing button 2 sets output off. If 

button 2 is not pressed, relay output sets off 

after  programmed time period 

(4)

 

E.

 Pressing transmitter button 

1 sets output on. Pressing 

button 2 sets output off. 

(1)

 

Output relay Monostable Mode (pulse) or Bistable Mode (on/off) is programmed in 
steps 2 and 3 of programming procedures. 

(2)

 

Delayed output set off reduces risk of unwanted interruptions in output set on con-
tinuity, due to interferences caused e.g. electric motors. Precise setting of this 
short delay timing is facilitated by programming 8-fold longer time delay of that 
needed. Example: to obtain 0.5s set off delay, programmed delay of 4..5s delay 
must be made (0.5 x 8=4). 

 

Number of remote control transmitters that can be used in this mode is limited to 
20. 

(3)

 

In modes A & B jumper JP1 selects timing of switch-over signal pulses at output S: 
jumper  On 

– 0.25s pulse, jumper Off  – 0.50s pulse. Longer timing of switch-over 

signal  pulses is necessary for certain acoustic signalling devices in which shorter 
pulses are not recognized properly. 

(4) 

This mode requires use of hand transmitter with two or more buttons.

 

KEELOQ

®

 Encoding System 

In the system, newly encoded control signal is generated and sent each time transmitter 
button is pressed. Receiver monitors code changes and responds to new code signals 
only.  Once  received  code  will  not  be  accepted  second  time.  This  allows  protection  of 
radio transmission signals from deliberate code grabbing and unauthorized use. 

Transmitter Memory 

As each transmitter generates specific dynamic code, receiver must “learn” and memo-
rize individual coding of every transmitter that will operate with the receiver. Therefore, 
receiver’s  memory  capacity  is  limited  to  112  transmitters.  Learning  113

th

  transmitter 

would delete first transmitter in memory, etc. Eliminating lost or stolen transmitters from 
receiver’s memory requires deleting all transmitters and learning all remaining transmit-
ters again. Deleting single transmitter from receiv

er’s memory is possible only with the 

use of the transmitter to be deleted (see pt 5 of programming procedures). 

Receiver Relay Output 

Receiver  is  equipped  with  galvanic  isolated  relay  output  with  NO  (normally  open) and 
NC  (normally  closed)  three  wiring  terminals 

– one common. The output switches over 

on  command  received  from  transmitter.  Details  are  shown  on  installation  diagram  in-
cluded in this manual. 

Signalling Output S 

The  receiver  features  one  open  collector  type  (OC)  signalling  output  for  connecting to 
external  acoustic  siren or light strobe. The output generates two pulses shorting to re-
ceiver’s  ground  (-V)  on  receiver’s relay set ON and one pulse on relay set OFF. Two 
pulses are generated also when pressed transmitter’s button is used to prolong set on 
timing  in  monostable  mode  only  (mode  A 

–  see  Table  above).  In  operation  modes  D 

and E (see Table above), in which button 1 sets output on and button 2 sets output off, 
two pulses are generated each time button 1 is pressed and one pulse each time button 
2 is pressed. 

LED Indication

  

Receiver is equipped with two colour LED signalling power supply connection and sta-
tus of relay output. It lights red when power is connected and relay output is not activat-
ed. When relay is set on it lights green. 

Receiver Installation 

Receiver’s  place  of  installation  should  be  dry  and  away  from  electromagnetic  power 
lines, radio transmitters, metal screening and other devices that may cause interference 
and  reduce  operation  range.  It  is  recommended  to  install  the  receiver  well  above 
floor/ground  level  and  test  practical operating range of transmitter-receiver set prior to 
firm installation. The level of hand transmitter signals and local unwanted radio interfer-
ence signals can be checked using optional Elmes RFM indicator. 

PROGRAMMING  PROCEDURES

 

Receiver  LED  low  flashing  green  in  confirms  properly  performed  programming  proce-
dure.  Fast  flashing  LED  in  red  indicates  programming  error.  Programming  procedure 
must be repeated. 

1. Learning transmitter(s) to receiver's memory (maximum 112): 

a) Press receiver's 

PRG1 

switch  for less than 2 seconds - LED lights green. 

b) Press shortly hand transmitter button once - receiver LED changes to red. 
c) Press shortly the same hand transmitter button again. 

2.  Programming  receiver  output  monostable  operation  mode  (pulse)  and  output 

set on timing: 

 

a) Press receiver's 

PRG1 

switch - LED lights green and after two seconds changes to 

red. Now release the switch. 

b) Press  hand  transmitter  button.  Relay  in  the  receiver  sets on. After required pulse 

time has lapsed press hand transmitter button again. Relay in receiver sets off. Af-
ter 2 seconds receiver's LED starts flashing green confirming end of the procedure. 

3.  Programming receiver output bistable (on/off) operation mode: 

a) Press receiver's 

PRG1 

switch - LED lights green and after two seconds changes to 

red. Now release the switch. 

b) Press  transmitter  button  three  times  with  less  than  2  seconds  intervals.  Receiver 

LED flashes green confirming end of the procedure. 

4. Deleting all transmitters in receiver memory: 

Press  and  hold  depressed 

PRG1 

switch  for  more  than  8  seconds.  Receiver  LED 

first lights green. After 2 seconds changes to red and after 6 seconds starts flash-
ing green. Now release the switch. To learn new transmitter(s) follow procedure 1 
above. 

5. Deleting single transmitter in receiver memory (condition: transmitter to be de-

leted is available): 

a) Press receiver's PRG1 switch  for less than 2 seconds - LED lights green. 
b) Press shortly button of the hand transmitter to be deleted - receiver LED changes 

to red. 

c) Perform one of the following steps: 

  Press button of any other Elmes Electornic made hand transmitter button, or 

  temporarily disconnect receiver power supply, or 

  wait round 30 seconds till receiver exits programming mode. 

Correct performing of this procedure is confirmed by LED flashing red (error indication). 

Advice  1:  Procedures  2,  3  and  5  can  be  performed  with  the  use  of  transmitter 

learned to the receiver memory. 

Advice 2: Time for performing procedures 1 and 5 above is limited to 30 seconds. 

If the procedures are not completed within this time period receiver exits 
programming mode and error is indicated.   

SPECIFICATION 

UMB100HT transmitter:  radiated power < 5mW, battery: 12V (23A). 
AN200HT transmitter:  radiated power < 10mW, battery: 9V (6F22). 
Receiver: 

- dynamic code system 

KEELOQ

®

 of  Microchip Corp. USA, 

- transmitter memory capacity: 112 (up to 20 in mode C), 
- superhet receiver module with sensitivity: -106 dBm, 
- power supply range: 11..17VDC, 50mA. 
- operating temperature range from -20 to + 55

°

C, 

- output relay max. power rating: 1A, 120VAC/30VDC, 
- monostable output mode timing: from 0,25s up to 4 hours, 
- bistable output mode: on/off, 
- signal output S (1A/60V max.)  OC type, 
- sabotage alarm terminals NC type (closed box). 
- external dimensions (h/w/l): 24/46/73 mm 

Low battery in transmitters is indicated either by its LED flashing (UMB100HT) or dim-
ming and failing to light (AN200HT). 

Manufacturer: 

ELMES ELEKTRONIK, 54-611 Wroclaw, Avicenny 2, PL 

 

tel. +48717845961, fax +48717845963 

Manufacturer’s Limited Warranty 

This  product  carries  two  year  manufacturer’s  warranty  as  from  the  date  of  purchase. 
The warranty is limited to the replacement of faulty original parts or repair defects of im-
proper  manufacture.  Damage,  misuse  or  improper  handling  by  the  user  or  installer as 
well as any alterations in product’s hardware or software caused by unauthorized per-
son violate warranty obligations and all due repair costs will be charged.

 

Elmes Electronic shall not be liable for any personal or material damage or loss result-
ing from any of 
its products di-
rect, 

indirect 

or  partial  use 
or  failure  to 
operate 
properly. 
 
 
 
 

WARNING!    Batteries  may  contain  substances  hazardous  to  human  health.  Do 
not place batteries in fire or household waste. Dispose of old batteries properly 
in accordance with local law regulations. Used batteries can always be disposed 
of at points of electronic waste collection.

 

IMPORTANT!

 

Output S must not

 be directly connected to  (+) pole of power supply (see dia-

gram above). 

UWAGA!

 

Wyjście S nie może

 być

 

bezpośrednio łączone do (+) zasilania (patrz schemat). 

Reviews: