E
G
LM-PA-G3-X Panic Button uide
Operating Life
>1 x 10 operations
8
Specifications
Temperature Range
-10°C to+40°C
Contact
Current Rating
1.0A Max
Resistance
<300mohms
Power Handling
10VA
Dimension
x
mm
s
62 80 x 27
Voltage Rating
30Vdc
X is colour code: ELM-PA-G3-W White, ELM-PA-G3-B Brass, ELM-PA-G3-SS Steel
ELM-PA-G3-BK Black
Elmdene International Ltd PAK
Iss 0
Page 1
2019
200464 June 2019
3D
Technical Support Line + 44 (0) 2392
696638
Setting reed - Normally Open (N.O.) or Normally Closed (N.C.)
Default is set to Normally closed. Please skip this section if this is the required setting.
1.
Tab
Tab
Follow steps 1&2 in reverse order to re-assemble. Take care not to damage the reed switch.
Wall Mounting
3. Drill holes to required depth and use appropriate wall plugs or fixings (No. 6 / 5mm).
2. Mark positions of holes on the wall.
5. Insert top
screw through PCB and plastic and screw into wall.
pan head
Take care not to snap
the PCB tamper breakout.
6. Use friction adjustment screw to ensure sliding mechanism does not move without being pushed
by buttons or reset key.
DO NOT OVERTIGHTEN
7. Angle lid as shown above. Slide upward
pushing lid closed. Fasten lid shut with screw.
before
1. Press both buttons to move mechanism out of the way and gain access to the bottom fixing hole.
4. Drive bottom
screw through base and into wall.
countersunk
Use of the PA button
Correct Use of PA Buttons
indicator will be red (latched).
2. To reset insert the key into the slot as shown.
4. Turn the key anticlockwise back to the start and remove it.
5. Indicator will now be yellow (ready).
3. Turn key clockwise as far as it will turn (about 120
degrees) to reset the PA.
1. Push both buttons together to operate. After use
PA buttons should be installed in accordance with any applicable
regulations relating to panic alarms. Potential users should be advised in
the use of the PA.
Page
2
Top mounting
screw hole
Bottom mounting
screw hole
2.
3.
Friction
Adjustment
Screw
Normally Closed
(Factory Default)
Normally
Open
2. Remove the sliding
mechanism (you may need
to loosen the
adjustment screw).
friction
3. Push out magnet from other
side and swap to desired
position.
1. Remove PCB by gently
bending the two tabs back
and pull the board up and
out.
Features include:
• Silent two button operation
S
•
uitable for use under the ACPO “10 point plan” for false PA reduction
• Integral, selectable resistor values for easy FSL connection to most alarm control
C
17
the
rity
•
ompliant with PD6662: 20 , and
requirements of EN 50131-1:2006, Secu
grade 3, Environmental class II.
• Spare terminals for connection of multiple units
panels.
• Key operated mechanical reset
• Cover and removal from wall tamper (normally closed)
Visual indication of ready or latched state
•
• Alternative double pole wiring option
• Selectable normally open or normally closed alarm contacts
A range of aesthetically pleasing two button panic alarm (PA) devices available with
white, brass or stainless steel appearance covers. Suitable for commercial and domestic
installation
black,
.
Panic alarm trigger device with two push buttons
Meets the requirements of
17 at Grade 3, Environmental Class II and
PD6662: 20
EN
50131-1:2006.