background image

E

 

 G

 

LM-PA-G3-X Panic Button uide

 

           

Operating Life 

>1 x 10   operations

 

8

Specifications

Temperature Range 

-10°C to+40°C

Contact  

 

 

Current Rating 

1.0A Max

 

 

 

Resistance 

<300mohms

 

 

 

Power Handling 

10VA

 

 

 

 

 

Dimension    

          

 x 

mm

s

62 80 x 27

Voltage Rating 

30Vdc 

 

   

 

 

X is colour code:    ELM-PA-G3-W White, ELM-PA-G3-B Brass, ELM-PA-G3-SS Steel
                               ELM-PA-G3-BK Black

     

  Elmdene International Ltd                            PAK

 

 Iss 0

                                                          Page 1

 2019

200464 June 2019

3D

       Technical Support Line  +  44 (0) 2392 

 

                

696638

Setting reed - Normally Open (N.O.) or Normally Closed (N.C.)

Default is set to Normally closed.  Please skip this section if this is the required setting.

1.

Tab

Tab

Follow steps 1&2 in reverse order to re-assemble. Take care not to damage the reed switch.

Wall Mounting

3. Drill holes to required depth and use appropriate wall plugs or fixings (No. 6 / 5mm).

2. Mark positions of holes on the wall.

5. Insert top 

 screw through PCB and plastic and screw into wall. 

pan head

Take care not to snap 

the PCB tamper breakout.

6. Use friction adjustment screw to ensure sliding mechanism does not move without being pushed 

by buttons or reset key. 

DO NOT OVERTIGHTEN

7. Angle lid as shown above. Slide upward 

 pushing lid closed. Fasten lid shut with screw.

before

1. Press both buttons to move mechanism out of the way and gain access to the bottom fixing hole.

4. Drive bottom 

 screw through base and into wall.

countersunk

Use of the PA button

Correct Use of PA Buttons

    indicator will be red (latched).

2. To reset insert the key into the slot as shown.

4. Turn the key anticlockwise back to the start and remove it.
5. Indicator will now be yellow (ready). 

3. Turn key clockwise as far as it will turn (about 120 

degrees) to reset the PA.

1. Push both buttons together to operate. After use

PA buttons should be installed in accordance with any applicable 
regulations relating to panic alarms. Potential users should be advised in 

the use of the PA. 

Page                   

2

Top mounting
screw hole

Bottom mounting
screw hole

2.

3.

Friction 

Adjustment
Screw

Normally Closed 
(Factory Default)

Normally 
Open 

2. Remove the sliding 

mechanism (you may need 
to loosen the 

 

adjustment screw).

friction 

3. Push out magnet from other 

side and swap to desired 
position.

1. Remove PCB by gently 

bending the two tabs back 

and pull the board up and 
out.

Features include:
     

• Silent two button operation 

     S

uitable for use under the ACPO “10 point plan” for false PA reduction

     

• Integral, selectable resistor values for easy FSL connection to most alarm control

     C

17

the 

 

rity

ompliant with PD6662: 20 , and 

requirements of EN 50131-1:2006, Secu

grade 3, Environmental class II.

     

• Spare terminals for connection of multiple units

panels. 

     

• Key operated mechanical reset

     

• Cover and removal from wall tamper (normally closed)

     Visual indication of ready or latched state

     

• Alternative double pole wiring option

     

• Selectable normally open or normally closed alarm contacts

A range of aesthetically pleasing two button panic alarm (PA) devices available with 
white, brass or stainless steel appearance covers. Suitable for commercial and domestic 
installation

black, 

Panic alarm trigger device with two push buttons

Meets the requirements of 

17 at Grade 3, Environmental Class II and 

 

PD6662: 20

EN

50131-1:2006. 

Reviews: