10
BA-en-2075-2111_ES47
3.4 Connecting the high voltage cable
Warning!
Electric shock hazard!
• Connect or disconnect the high voltage cables / the bars only with the
power supply switched off!
• Connect the discharging bars to the power supply using the prefabri-
cated high voltage cable.
Method:
• Remove the cover of the power supply (see Fig. 1).
• Remove the nut from the connection at the high voltage cable.
• Insert the connection into the provided opening of the housing.
• Clamp the core of the high voltage cable to the high voltage socket X2.
• Fix the connection inside the unit with the locknut.
• Plug the flat connector of the cable shielding onto ground connection
X1.
Warning!
Terminals at the housing that are not used must be closed with blanking
plugs.
Fig. 3:
High voltage cable
without flexible
tube
Z-1
1
48
32
y_
1
Summary of Contents for ES47 Series
Page 2: ...2 BA en 2075 2111_ES47...
Page 16: ...16 BA en 2075 2111_ES47 8 Dimensions Fig 5 Dimensions ES47 Power Supply Z 113409by...
Page 18: ...18 BA en 2075 2111_ES47...
Page 19: ......