72/112
WL31/WL31TG
8.53 PARAMETERS - ADVANCED [73]
Menu > Parameters > Parameters - Advanced
Authorization level:
TECHNICIAN
Sub menu
Fast code
Advanced Alarm Count
730
Network time OFF
731
Purpose:
Alarm count
: this shows the number of times an intrusion alarm must be repeated before its repetition is blocked.
The count is reset when the system is reactivated or automatically every 24 hours. Possible adjustments are: 1, 2,
4, 6, 8 or NO (alarm goes on buzzing).
How to do it:
1. Press
OK
to access «Alarm count», then press
OK
again.
2. Select the required number of repetitions with the
and
keys and confirm by using the
OK
keys.
Network time OFF
: determines the time after which, in case of power supply present, the control panel signals
network off (5 min, 1 hour, 2 hours, 4 hours).
How to do it:
3.
Press
OK
to access «Network time OFF», then press
OK
again.
4.
Select the required interval with the
and
keys and confirm by using the OK key.